「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 278
Aug 01/02R CES
(2) If the fault does not move with the CPC 2:
(a) Swap back the CPC 2 (12HL) and the CPC 1 (11HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(b) Replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2 (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
NOTE : The electronic module 2 is connected to the electrical
____
connector 10HL-B.
(3) If the fault continues:
(a) Do a check and repair the wiring from the:
- CPC 2 controller (12HL-AA) pins 7A, 8A, 9A and 10A to the OFV controller (10HL-B) pins R, P, N and M (Ref. ASM 21-31/02).
(b) Do a check of the earthing resistance at the return ground connections (Ref. AMM 21310076000100) on:
- the CPC 2 connector 12HL-AC, pin 2 and on,
- the electronic module 2 connector 10HL-B, pin J. NOTE : The resistance value must be smaller than 20 m.ohms.
____
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 279
Aug 01/02R
CES TASK 21-31-00-810-839
Cabin Pressure Controller 1 Fault (59)
1. Possible Causes
_______________
- CONTROLLER-CABIN PRESSURE 1 (11HL)
- VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1
- RELAY-AUTO MODE DRIVE SHUT OFF (17HL)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-31-00-710-002 Operational Test of the Pressure Control and Monitoring
AMM 21-31-00-760-001 Resistance Check of the Return Ground Connections -Cabin Pressure Controller (CPC) 1 (11HL) and 2 (12HL) and the Electronic Modules 10HL-1 and 10HL-2
AMM 21-31-34-000-001 Removal of the Cabin Pressure Controller (11HL,12HL) AMM 21-31-34-400-001 Installation of the Cabin Pressure Controller (11HL,12HL) AMM 21-31-51-000-002 Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) AMM 21-31-51-400-002 Installation of the Outflow Valve (10HL) -Electronics Module 10HL-1 (10HL-2) ASM 21-31/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
4. Fault Isolation
_______________
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message,
- PRESS CONTROLLER 1 (59):
- swap the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 280
Aug 01/02R
CES
(1) If the fault moves with the CPC 1:
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(a) Replace the CONTROLLER-CABIN PRESSURE 1 (11HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(2) If the fault does not move with the CPC 1:
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(a) Replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
NOTE : The electronic module 1 is connected to the electrical
____
connector 10HL-A.
(3) If the fault continues:
- replace the RELAY-AUTO MODE DRIVE SHUT OFF (17HL).
(4) If the fault continues:
- do a check and repair the wiring from the:
- CPC 1 connector (11HL-AA) pin 15D to the OFV connector (10HL-A) pin L (Ref. ASM 21-31/01).
(a) Do a check of the earthing resistance at the return ground connections (Ref. AMM TASK 21-31-00-760-001) on:
- the CPC 1 connector 11HL-AC, pin 2 and on,
- the electronic module 1 connector 10HL-A, pin J. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(117)