R **ON A/C 106-149, 211-299, 301-399, 401-499,
A. If there is oil in the APU bleed-air duct-elbow:
- do a check for external oil leaks of the APU.
(1) If there is an external oil leakage:
- do the necessary steps to stop the external oil leakage,
- clean and install the APU bleed-air duct-elbow (Ref. AMM TASK 49-11-11-400-003).
- do the trouble shooting of the APU (Ref. TASK 49-00-00-810-921) and the decontamination of the ECS (Ref. AMM TASK 21-00-00-615-001) or (Ref. AMM TASK 21-00-00-615-002).
(2) If there are no external oil leaks:
- clean the APU bleed-air duct-elbow,
- install the APU bleed-air duct elbow (Ref. AMM TASK 49-11-11-400-003),
- do the trouble shooting of the APU (Ref. TASK 49-00-00-810-921) and the decontamination of the ECS (Ref. AMM TASK 21-00-00-615-001) or (Ref. AMM TASK 21-00-00-615-002).
- do the trouble shooting of the engines (Ref. TASK 71-00-00-810-802).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 211-299, 301-399, ∞∞21-00-00∞∞∞∞∞∞∞∞∞∞Page 203
401-499, Aug 01/05 CES
**ON A/C ALL
TASK 21-00-00-810-802 Unsatisfactory Cabin Air Quality
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
21-00-00-810-801 Oil in the Air Conditioning System SIL 21-132
3. Fault Confirmation
__________________
A. Not applicable
4. Fault Isolation
_______________
A. If the cabin has an unsatisfactory air quality (smell of oil):
- (Ref. TASK 21-00-00-810-801)
B. If the cabin has an unsatisfactory air quality:
- (Ref. SIL 21-132)
AIR DISTRIBUTION AND RECIRCULATION - FAULT ISOLATION PROCEDURES
_______________________________________________________________
TASK 21-21-00-810-801
Cabin Recirculation Fault (Fan 1 / Supply)
1. Possible Causes_______________
R R R R R - FILTER-RECIRCULATION (4012HM) - FAN RECIRCULATION (15HG) - P/BSW-VENTILATION/CAB FANS (4HG) - RELAY-FAN FAULT SUPPRESS (16HG) - RELAY-L FAN POWER (5HG) - RELAY-L FAN CONTROL (7HG) - RELAY-L FAN FAULT (10HG) - PUSHBUTTON SWITCH-VENTILATION/CAB FANS (4HG) - RELAY-FAN FAULT SUPPRESSION (16HG) - RELAY-L FAN POWER (5HG) - RELAY-L FAN CTL (7HG) - RELAY-L FAN FAULT (10HG) - wiring
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM AMM AMM AMM AMM ASM ASM ASM 21-21-00-710-001 21-21-41-000-001 21-21-41-400-001 21-21-51-000-001 21-21-51-400-001 21-21/0121-21/0121-63/01 Operational Test of the Cabin Recirculation Fans 14HG and 15HG.Removal of the Recirculation Filter 4012HM (4013HM)Installation of the Recirculation Filter 4012HM (4013HM)Removal of the Cabin Recirculation Fans 15HG and 14HGInstallation of the Cabin Recirculation Fans 15HG and 14HG
3. Fault Confirmation__________________
A. Do the operational test of the cabin recirculation fans 14HG and 15HG (Ref. AMM TASK 21-21-00-710-001).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message RECIRC FAN 1 OR SPLY:
- make sure that the recirculation filter (4012HM) housing and the adjacent area is clean.
- remove the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-000-001).
(1) If the recirculation fan (15HG) operates correctly:
- do a check of the recirculation filter (4012HM) for contamination.
(a) If the filter is clogged:
- replace the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-001).
(b) If the filter is not clogged:
- install the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-400-001).
(2) If the recirculation fan (15HG) does not operate:
- do a check of the PUSHBUTTON SWITCH-VENTILATION/CAB FANS (4HG) and replace it if necessary (Ref. ASM 21-21/01).
(a) If the fault continues:
- do a check of the RELAY-FAN FAULT SUPPRESSION (16HG) and replace it if necessary (Ref. ASM 21-21/01). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(51)