• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:13来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

AMM 21-31-00-710-002 Operational Test of the Pressure Control and Monitoring AMM 21-31-51-000-002 Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) AMM 21-31-51-400-002 Installation of the Outflow Valve (10HL) -Electronics Module 10HL-1 (10HL-2)
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
 4. Fault Isolation
_______________
 A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives one of the maintenance messages which follow, OUTFLOW VALVE ELEC 2 (64), OUTFLOW VALVE ELEC 2 (65), OUTFLOW VALVE ELEC 2 (66), OUTFLOW VALVE ELEC 2 (67), OUTFLOW VALVE ELEC 2 (72), OUTFLOW VALVE ELEC 2 (76), OUTFLOW VALVE ELEC 2 (83) or, OUTFLOW VALVE ELEC 2 (87):
 - replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2 (referred to as OFV (10HL)) (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
 NOTE : The electronic module 2 is connected to the electrical connector
____
 10HL-B.

 B. Do the test as given in the Para. 3.A.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 271
 Aug 01/02R CES

 TASK 21-31-00-810-835


 Outflow Valve Electronic Module 1 Fault (77)
 1. Possible Causes
_______________
 - VALVE-OUTFLOW (10HL)

 - VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1

 - VALVE-OUTFLOW (10HL), FEEDBACK ASSEMBLY

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-31-00-710-002 Operational Test of the Pressure Control and
 Monitoring AMM 21-31-51-000-001 Removal of the Outflow Valve 10HL (From Inside) AMM 21-31-51-000-002 Removal of the Outflow Valve (10HL) - Electronics
 Module 10HL-1 (10HL-2) AMM 21-31-51-000-005 Removal of the Outflow Valve (10HL) - Feedback
 Assembly 10HL-6 AMM 21-31-51-400-001 Installation of the Outflow Valve 10HL (From Inside) AMM 21-31-51-400-002 Installation of the Outflow Valve (10HL) -
Electronics Module 10HL-1 (10HL-2) AMM 21-31-51-400-005 Installation of the Outflow Valve (10HL) - Feedback Assembly 10HL-6 ASM 21-31/01
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 272
 Aug 01/02R
 CES

 4. Fault Isolation
_______________

 A. Fault Isolation
 NOTE : This procedure is only applicable for Outflow Valve Part Numbers
____
 9023-15703-81 and previous.

 (1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message, OUTFLOW VALVE ELEC 1 (77):
 - replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 (referred to as OFV (10HL)) (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
 NOTE : The electronic module 1 is connected to the electrical
____
 connector 10HL-A.

 (a) If the fault continues:

 - replace the VALVE-OUTFLOW (10HL), FEEDBACK ASSEMBLY (referred to as OFV (10HL)) (Ref. AMM TASK 21-31-51-000-005) and (Ref. AMM TASK 21-31-51-400-005).

 (b) If the fault continues:


 - do a check and repair the wiring from the: OFV connector (10HL-D) pins A, B, C, D and E to the OFV connector (10HL-A) pins A, B, C, E and F (Ref. ASM 21-31/01).
 B. Fault Isolation
 NOTE : This procedure is only applicable for Outflow Valve Part Number
____
 20790-01AA and onwards.

 (1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message, OUTFLOW VALVE ELEC 1 (77):
 - replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 (referred to as OFV (10HL)) (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
 NOTE : The electronic module 1 is connected to the electrical
____
 connector 10HL-A.

 (a) If the fault continues:

 - replace the VALVE-OUTFLOW (10HL) (Ref. AMM TASK 21-31-51-000-001) and (Ref. AMM TASK 21-31-51-400-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(114)