CARGO COMPARTMENT VENTILATION 21-28-00
TASK SUPPORTING DATA 301 001-049, 051-099 101-105, 151-199 201-299, 301-302
PRESSURE CONTROL AND MONITORING 21-31-00
FAULT ISOLATION PROCEDURES 201 ALL
Fault Codes - Fault Isolation 201 ALL
Procedure Index
Cabin Pressure Controller 1 Fault 206 ALL
Manual Mode - CPC Fault 208 ALL
Outflow Valve Auto Motor 1 or 2 210 ALL
Fault
Outflow Valve Feedback Assembly 212 ALL
Fault (CPC 1)
Cabin Pressure Controller 2 Fault 214 ALL
Outflow Valve Fault (05), (11), 216 ALL
(24), (25), (26), (29), (60)
Safety Valves open 218 ALL
Excessive Cabin Altitude 220 ALL
Low Differential Pressure 227 ALL
Landing Field Elevation Fault 228 ALL
CPC 1 receives no Data from the 230 ALL
FMGS
CPC 2 receives no Data from the 233 ALL
FMGS
CPC 1 receives no Data from the 236 ALL
ADIRS
CPC 2 receives no Data from the 239 ALL
ADIRS
EIU Signal Replaced 242 ALL
LGCIU Signal Mismatch 244 ALL
DMU receives no Data from the CPC 246 ALL
1
DMU receives no Data from the CPC 248 ALL
2
Outflow Valve does not close in 250 ALL
the Ditching Configuration
21-CONTENTS Page 3 May 01/05 R CES
CHAPTER 21
__________
AIR CONDITIONING
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Outflow Valve does not operate 251 ALL during the Emergency Ram Air Configuration Outflow Valve does not operate in 252 ALL the Manual Mode MODE SEL Pushbutton Switch FAULT 254 ALL Legend on Outflow Valve Feedback Assembly 256 ALL Fault (CPC 2) Excessive Cabin Altitude 259 ALL associated with CAB PR SYS FAULT Outflow Valve Fault (33) (81) 261 ALL Outflow Valve Electronic Module 1 262 ALL Fault (04) Outflow Valve Electronic Module 2 264 ALL Fault (04) Outflow Valve Electronic Module 1 266 ALL Fault (52) Outflow Valve Electronic Module 2 268 ALL Fault (52) Outflow Valve Electronic Module 1 270 ALL Fault (64), (65), (66), (67), (72), (76), (83), (87) Outflow Valve Electronic Module 2 271 ALL Fault (64), (65), (66), (67), (72), (76), (83), (87) Outflow Valve Electronic Module 1 272 ALL Fault (77) Outflow Valve Electronic Module 2 274 ALL Fault (77) Cabin Pressure Controller 1 Fault 276 ALL
(51
)
Cabin Pressure Controller 2 Fault 278 ALL
(51
)
Cabin Pressure Controller 1 Fault 280 ALL
(59
)
Cabin Pressure Controller 2 Fault 282 ALL
(59
)
CPC 1 - MCDU Fault 284 ALL
Outlow Valve Mistakenly Reported 286 ALL
Not Open On Ground
PRESSURE CONTROL AND MONITORING 21-31-00
TASK SUPPORTING DATA 301 ALL
Cabin Pressure Controller 301 ALL
21-CONTENTS Page 4 Feb 01/05 R CES
CHAPTER 21
__________
AIR CONDITIONING
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ CFDS Fault Information 301 ALL Additional BITE Fault 301 ALL Information Handling
CARGO COMPARTMENT HEATING 21-43-00
FAULT ISOLATION PROCEDURES 201 ALL AFT Cargo-Duct Temperature-Sensor 201 ALL Fault AFT Cargo-Compartment 203 ALL Temperature-Sensor Fault AFT Cargo-Compartment 205 ALL Temperature-Selector Function Fault AFT Cargo-Compartment Trim-Air 206 ALL Regulation Fault AFT Cargo-Compartment Trim Air 208 ALL Pressure Regulating Fault AFT Cargo-Compartment Heating 210 ALL Controlling Fault AFT Cargo-Compartment Trim-Air 212 ALL Pressure Regulating Fault AFT Cargo Temperature Sensor Fault 213 ALL Electrical Circuit Fault 214 ALL Aft Trim Air Pressure Regulating 216 ALL Valve (TAPRV) Control Circuit Fault
CARGO COMPARTMENT HEATING 21-43-00
TASK SUPPORTING DATA 301 ALL
AIR COOLING 21-50-00
___________
FAULT ISOLATION PROCEDURES 201 ALL Belly-Fairing Blow-Out Panel in 201 ALL open position
FLOW CONTROL AND INDICATING 21-51-00
FAULT ISOLATION PROCEDURES 201 ALL Flow Selection Fault 201 ALL Mixer Flap Actuator Fault 205 ALL Pack 1 Flow Control Valve (Pack 1 208 ALL Flow Control Unit) Fault Pack 2 Flow Control Valve (Pack 2 213 ALL Flow Control Unit) Fault Pack 1 Flow Sensor Fault 218 ALL Pack 2 Flow Sensor Fault 220 ALL
21-CONTENTS Page 5 Feb 01/05 R CES
CHAPTER 21
__________
AIR CONDITIONING
中国航空网 www.aero.cn
航空翻译 www.aviation.cn