 of the AEVC AMM 21-26-00-710-009 Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC AMM 21-26-11-000-001 Removal of the Blower and Extract Fan Pressure Switches (17HQ, 19HQ, 30HQ) AMM 21-26-11-400-001 Installation of the Blower and Extract Fan Pressure Switches (17HQ, 19HQ, 30HQ) AMM 21-26-34-000-001 Removal of the Avionics Equipment Ventilation Computer (AEVC) (10HQ) AMM 21-26-34-400-001 Installation of the Avionics Equipment Ventilation
 Computer (AEVC) (10HQ) AMM 21-26-43-000-003 Removal of the Filter Assembly (2082HM,2083HM) AMM 21-26-43-400-003 Installation of the Filter Assembly (2082HM,2083HM) AMM 21-26-43-600-001 Servicing of the Demister Filter AMM 21-26-43-600-007 Servicing of the Demister Filter AMM 21-26-43-920-001 Replacement of the Filter Cartridge
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 223
 May 01/05 CES


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 21-26-51-000-001 Removal of the Blower and Extract Fans (18HQ,20HQ) AMM 21-26-51-400-001 Installation of the Blower and Extract Fans (18HQ, 20HQ) AMM 21-26-52-000-001 Removal of the Avionics Ventilation Skin Air Inlet Valve (15HQ) AMM 21-26-52-400-001 Installation of the Avionics Ventilation Skin Air Inlet Valve (15HQ) AMM 21-26-55-000-001 Removal of the Avionics Ventilation Skin Exchanger Inlet Bypass Valve (16HQ) AMM 21-26-55-400-001 Installation of the Avionics Ventilation Skin Exchanger Inlet Bypass Valve (16HQ) ASM 21-26/03
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) (Ref. AMM TASK 21-26-00-710-001).

 (2) Read the LAST LEG REPORT (Ref. AMM TASK 21-26-00-710-009).

 (3) Read the CLASS 3 message (Ref. AMM TASK 21-26-00-710-008).


 4. Fault Isolation
_______________
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU AIR COND/AVNCS/VENT/MONG 3HQ Y17 123VU AVNCS VENT/BLOWER/FAN 1HQ AD10
R **ON A/C 001-049, 051-099, 101-105, 301-399, 401-499,
 B. Possible Maintenance Messages (one or more of these messages)
 SKIN AIR INLET V 15HQ
 ISOL V 24HQ
 BLOWER FAN 20HQ
 PRESSURE SWITCH 17HQ
 PRESSURE SWITCH 19HQ
 DUCT TEMP SENSOR 26HQ

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 224
 Aug 01/05 CES


 (1) If the test gives the maintenance message SKIN AIR INLET V 15HQ, replace the VALVE-SKIN AIR INLET, AVNCS VENT (15HQ) (Ref. AMM TASK 21-26-52-000-001) and (Ref. AMM TASK 21-26-52-400-001).

 (2) If the test gives the maintenance message ISOL V 24HQ, replace the VALVE-SKIN EXCHANGER ISOLATION, AVNCS VENT (24HQ) (Ref. AMM TASK 21-26-55-000-001) and (Ref. AMM TASK 21-26-55-400-001).

 (3) If the test gives the maintenance message DUCT TEMP SENSOR 26HQ, replace the SENSOR-DUCT TEMP, AVNCS VENT (26HQ) (Ref. TASK 21-26-00-810-818).

 (4) If the test gives the maintenance message BLOWER FAN 20HQ:

 - make sure that the avionics ventilation filter is not clogged. If necessary, replace it (Ref. AMM TASK 21-26-43-600-001).

 - do a check of the status of the circuit breaker (1HQ).

 

 (5) If the test also gives the maintenance message PRESSURE SW 19HQ and/or PRESSURE SW 17HQ:

 - do the procedures (Ref. TASK 21-26-00-810-814) and (Ref. TASK 21-26-00-810-815).

 (6) If the circuit breaker (1HQ) is closed:


 - do a check for 115VAC at pins A/J, A/K, A/L of the blower fan (20HQ).
 (a) If there is no 115VAC:
 - do a check for 115VAC at pins T1, T2, T3 of the blower fan control-contactor (8HQ).
 1 If there is no 115VAC:
_
 - do a check for a short to ground at the wiring between the blower fan control-contactor (8HQ) and the circuit breaker (1HQ), pins L1, L2, L3 and respectively pins A2, B2, C2 (Ref. ASM 21-26/03).
 a If there is a short to ground:
_ - repair the related wiring.
 b If there is no short to ground:
_
 - replace the C/B-AVNCS BLOWER FAN (1HQ)
 2 If there is 115VAC:
_
 - do a check of the status of the circuit breaker (3HQ).
 