B. Do the operational test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 252
May 01/05R
CES TASK 21-26-00-810-816
Warning of the Extract-Fan Pressure Switch Inoperative
1. Possible Causes
_______________
- PRESS SW-EXTRACT FAN, AVNCS VENT (30HQ)
- AEVC (10HQ)
- wiring between the AEVC (10HQ) and the extract fan pressure switch (30HQ)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-26-00-710-001 Operational Check of System via MCDU AMM 21-26-11-000-001 Removal of the Blower and Extract Fan Pressure Switches (17HQ, 19HQ, 30HQ) AMM 21-26-11-400-001 Installation of the Blower and Extract Fan Pressure Switches (17HQ, 19HQ, 30HQ) AMM 21-26-34-000-001 Removal of the Avionics Equipment Ventilation Computer (AEVC) (10HQ) AMM 21-26-34-400-001 Installation of the Avionics Equipment Ventilation Computer (AEVC) (10HQ) ASM 21-26/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) (Ref. AMM TASK 21-26-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message PRESSURE SW 30HQ:
- replace the PRESS SW-EXTRACT FAN, AVNCS VENT (30HQ) (Ref. AMM TASK 21-26-11-000-001) and (Ref. AMM TASK 21-26-11-400-001).
(1) If the fault continues:
- do a check and repair the wiring between the AEVC (10HQ) and the extract fan pressure switch (30HQ), pins AB/8B and pins A/A (Ref. ASM 21-26/02).
(a) If the fault continues:
- replace the AEVC (10HQ) (Ref. AMM TASK 21-26-34-000-001) (Ref. AMM TASK 21-26-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 253
May 01/05R CES
B. Do the operational test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 254
May 01/05R
CES
TASK 21-26-00-810-817
Unwanted Warning of the Duct Temperature Sensor
1. Possible Causes
_______________
- SENSOR-DUCT TEMP, AVNCS VENT (26HQ)
- AEVC (10HQ)
- CARTRIDGE-AVNCS VENT FILTER (2082HM)
- wiring between the AEVC (10HQ) and the duct temperature sensor (26HQ)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-26-00-710-001 Operational Check of System via MCDU AMM 21-26-12-000-001 Removal of the Avionics Ventilation Duct Temperature Sensor (26HQ) AMM 21-26-12-400-001 Installation of the Avionics Ventilation Duct Temperature Sensor (26HQ) AMM 21-26-34-000-001 Removal of the Avionics Equipment Ventilation Computer (AEVC) (10HQ) AMM 21-26-34-400-001 Installation of the Avionics Equipment Ventilation
Computer (AEVC) (10HQ) AMM 21-26-43-600-007 Servicing of the Demister Filter AMM 21-26-43-920-001 Replacement of the Filter Cartridge ASM 21-26/03
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) (Ref. AMM TASK 21-26-00-710-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 255
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(78)