EMERGENCY RAM AIR INLET 21-55-00
FAULT ISOLATION PROCEDURES 201 ALL
Emergency Ram Air Inlet Fault 201 ALL
Emergency Ram Air Inlet does not 203 ALL
close in Ditching Configuration
Emergency Ram Air Inlet Fault 204 ALL
PACK TEMPERATURE CONTROL 21-61-00
FAULT ISOLATION PROCEDURES 201 ALL
Pack 1 Overheat 201 ALL
Pack 2 Overheat 210 ALL
Pack 1 Fault 219 ALL
Pack 2 Fault 228 ALL
Pack Controller 1 (ACSC1) Fault 237 ALL
Pack Controller 2 (ACSC2) Fault 240 ALL
21-CONTENTS Page 6 Aug 01/05 R CES
CHAPTER 21
__________
AIR CONDITIONING
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________
Pack 1 and Pack 2 Inoperative 244 ALL
Pack 1 is incorrectly off 246 ALL
Pack 2 is incorrectly off 248 ALL
Pack 1 Water Extractor Temperature 250 ALL
Sensor Fault
Pack 2 Water Extractor Temperature 252 ALL
Sensor Fault
Pack 1 Air Inlet Flap Actuator 254 ALL
Fault
Pack 2 Air Inlet Flap Actuator 257 ALL
Fault
Pack 1 Air Outlet Flap Actuator 261 001-003, 051-054
Fault
Pack 2 Air Outlet Flap Actuator 263 001-003, 051-054
Fault
Pack 1 Turbine Bypass Valve Fault 265 ALL
Pack 2 Turbine Bypass Valve Fault 268 ALL
Pack 1 Anti Ice Valve Fault 271 ALL
Pack 2 Anti Ice Valve Fault 274 ALL
Pack 1 Electrical Component with 277 ALL
Short Circuit (AIR PACK 1 REGUL
FAULT)
Pack 2 Electrical Component with 294 ALL
Short Circuit (AIR PACK 2 REGUL
FAULT)
Pack 1 Pressure Inlet Sensor Fault A211 001-049, 051-099
101-149, 151-199
201-299, 301-399
Pack 2 Pressure Inlet Sensor Fault A213 001-049, 051-099
101-149, 151-199
201-299, 301-399
Pack 1 Compressor Temperature A215 ALL
Sensor Fault
Pack 2 Compressor Temperature A217 ALL
Sensor Fault
Pack 1 Compressor Overheat A219 ALL
Temperature Sensor Fault
Pack 2 Compressor Overheat A221 ALL
Temperature Sensor Fault
Pack 1 Outlet Temperature Sensor A223 ALL
Fault
Pack 2 Outlet Temperature Sensor A225 ALL
Fault
Pack 1 High Discharge Temperature A227 ALL
Pack 2 High Discharge Temperature A240 ALL
DMU receives no Data from the PC 1 A253 ALL
21-CONTENTS Page 7 Aug 01/05 R CES
CHAPTER 21
__________
AIR CONDITIONING
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ (ACSC 1) DMU receives no Data from the PC 2 A255 ALL (ACSC 2) Pack 1 Controller (ACSC 1) Pin A257 ALL Program Mismatch Pack 2 Controller (ACSC 2) Pin A259 ALL Program Mismatch Pack 1 Compressor Temperature A261 001-049, 051-099 Sensor / Compressor Overheat 101-149, 151-199 Sensor Disagree 201-299, 301-399 Pack 2 Compressor Temperature A263 001-049, 051-099 Sensor / Compressor Overheat 101-149, 151-199 Sensor Disagree 201-299, 301-399 Pack 1 Air Inlet Actuator Fault A265 ALL Pack 2 Air Inlet Actuator Fault A268 ALL Pack 1 Air Outlet Actuator Fault A271 001-003, 051-054 Pack 2 Air Outlet Actuator Fault A273 001-003, 051-054 Pack 1 Controller (ACSC 1) Fault -A275 ALL Outlet Temperature / Compressor Outlet Temperature Indication replaced by Amber XX Pack 2 Controller (ACSC 2) Fault -A277 ALL Outlet Temperature / Compressor Outlet Temperature Indication replaced by Amber XX Pack 1 Control - No Test Result A279 ALL Pack 2 Control - No Test Result A280 ALL Pack 1 Electrical Component with A281 001-049, 051-099 Short Circuit (AIR PACK 1) 101-149, 151-199