On the ECAM BLEED page:
- the pack 1 flow indication showsbetween the 11 oIclock and the 1oIclock positions.
On the ECAM BLEED page:
- the pack 1 flow indication showsbetween the 1 oIclock and the HIpositions.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞21-51-00∞∞∞∞∞∞∞∞∞∞Page 238
201-299, 401-499, Aug 01/05 CES
**ON A/C 301-399,
D. Test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the AIR COND panel 30VU:
- push the ECON FLOW pushbutton switch to the on position (the ON legend comes on) and wait for 120 sec.
2. On the AIR COND panel 30VU:
- push the PACK 2 P/BSW and wait for 120 sec.
3. On the AIR COND panel 30VU:
- push the PACK 2 P/BSW.
4. On the AIR COND panel 30VU:
- push the ECON FLOW pushbutton switch to the off position (the ON legend goes off) and wait for 120 sec.
**ON A/C ALL
4. Fault Isolation
_______________
R **ON A/C 001-003, 051-054,On the ECAM BLEED page:
- the pack 1 flow indication showsbetween the LO and the 11 oIclockpositions.
On the AIR COND panel 30VU:
- the OFF light of the PACK 2 P/BSWcomes on.
On the ECAM BLEED page:
- the pack 1 flow indication shows between the 1 oIclock and the HI positions.
On the AIR COND panel 30VU:
- the OFF light of the PACK 2 P/BSW goes off.
On the ECAM BLEED page:
- the pack 1 flow indication showsbetween the 11 oIclock and the 1oIclock positions.
中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(142)