(b) If the fault continues:
- do a check of the RELAY-L FAN POWER (5HG) and replace it if necessary (Ref. ASM 21-21/01).
(c) If the fault continues:
- do a check of the RELAY-L FAN CTL (7HG) and replace it if necessary (Ref. ASM 21-21/01).
(d) If the fault continues:
- do a check of the RELAY-L FAN FAULT (10HG) and replace it if necessary (Ref. ASM 21-21/01).
(e) If the fault continues:
- replace the FAN RECIRCULATION (15HG) (referred to as FAN (15HG)) (Ref. AMM TASK 21-21-51-000-001) and (Ref. AMM TASK 21-21-51-400-001).
(f) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-21/01) and (Ref. ASM 21-63/01) from:
- the FAN (15HG) to the CB (1HG),
- the FAN (15HG) to the CB (2HG),
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-21-00∞∞∞∞∞∞∞∞∞∞Page 202
Aug 01/05 CES
- the FAN (15HG) to ground,
- the RELAY (7HG) to the RELAY (5HG),
- the RELAY (7HG) to ground,
- the RELAY (10HG) to the RELAY (5HG),
- the RELAY (10HG) to ground,
- the RELAY (10HG) to the ZC (8HK),
- the RELAY (16HG) to the SW (4HG) and,
- the RELAY (16HG) to ground.
R **ON A/C 401-499,
A. If the test gives the maintenance message RECIRC FAN 1 OR SPLY(15HG):
- make sure that the recirculation filter (4012HM) housing and the adjacent area is clean.
- remove the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-000-001).
(1) If the recirculation fan (15HG) operates correctly:
- do a check of the recirculation filter (4012HM) for contamination.
(a) If the filter is clogged:
- replace the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-001).
(b) If the filter is not clogged:
- install the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-400-001).
(2) If the recirculation fan (15HG) does not operate:
- do a check of the P/BSW-VENTILATION/CAB FANS (4HG) and replace it if necessary (Ref. ASM 21-21/01).
(a) If the fault continues:
- do a check of the RELAY-FAN FAULT SUPPRESS (16HG) and replace it if necessary (Ref. ASM 21-21/01).
(b) If the fault continues:
- do a check of the RELAY-L FAN POWER (5HG) and replace it if necessary (Ref. ASM 21-21/01).
(c) If the fault continues:
- do a check of the RELAY-L FAN CONTROL (7HG) and replace it if necessary (Ref. ASM 21-21/01).
(d) If the fault continues:
- do a check of the RELAY-L FAN FAULT (10HG) and replace it if necessary (Ref. ASM 21-21/01).
(e) If the fault continues:
- replace the FAN RECIRCULATION (15HG) (Ref. AMM TASK 21-21-51-000-001) and (Ref. AMM TASK 21-21-51-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-21-00∞∞∞∞∞∞∞∞∞∞Page 203
Aug 01/05 CES (f) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-21/01) and (Ref. ASM 21-63/01) from:
- the FAN (15HG) to the CB (1HG),
- the FAN (15HG) to the CB (2HG),
- the FAN (15HG) to ground,
- the RELAY (7HG) to the RELAY (5HG),
- the RELAY (7HG) to ground,
- the RELAY (10HG) to the RELAY (5HG),
- the RELAY (10HG) to ground,
- the RELAY (10HG) to the ACSC1 (47HH),
- the RELAY (16HG) to the SW (4HG) and,
- the RELAY (16HG) to ground.
**ON A/C ALL
B. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-21-00∞∞∞∞∞∞∞∞∞∞Page 204
May 01/05R
CES
TASK 21-21-00-810-802
Cabin Recirculation Fault
1. Possible Causes
_______________
- FILTER-RECIRCULATION (4012HM)
- FILTER-RECIRCULATION (4013HM)
- FAN RECIRCULATION (15HG)
- FAN-RECIRCULATION (14HG) R - P/BSW-VENTILATION/CAB FANS (4HG) R - RELAY-FAN FAULT SUPPRESS (16HG) R - RELAY-L FAN POWER (5HG) R - RELAY-R FAN POWER (6HG) R - RELAY-L FAN CONTROL (7HG) R - RELAY-R FAN CONTROL (8HG) R - RELAY-L FAN FAULT (10HG) R - RELAY-R FAN FAULT (9HG)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn