REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 21-26-00-710-001 Operational Check of System via MCDU AMM 21-26-13-000-001 Removal of the Avionics Ventilation Skin Temperature Sensor (28HQ) AMM 21-26-13-400-001 Installation of the Avionics Ventilation Skin Temperature Sensor (28HQ) AMM 21-26-34-000-001 Removal of the Avionics Equipment Ventilation Computer (AEVC) (10HQ) AMM 21-26-34-400-001 Installation of the Avionics Equipment Ventilation Computer (AEVC) (10HQ) ASM 21-26/02
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) (Ref. AMM TASK 21-26-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message SKIN TEMP SENSOR 28HQ:
 - replace the SENSOR-SKIN TEMP, AVNCS VENT (28HQ) (Ref. AMM TASK 21-26-13-000-001) and (Ref. AMM TASK 21-26-13-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring between the AEVC (10HQ) and the skin temperature sensor (28HQ) , pins AB/1D, AB/2D, AB/3D and pins A/A, A/B, A/C (Ref. ASM 21-26/02).
 (a) If the fault continues:
 - replace the AEVC (10HQ) (Ref. AMM TASK 21-26-34-000-001) and (Ref. AMM TASK 21-26-34-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 259
 May 01/05R CES


 B. Do the operational test given in Para. 3.

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 260
 May 01/05R
 CES

 TASK 21-26-00-810-820


 Failure of the Skin Exchanger-Outlet Bypass Valve
 1. Possible Causes_______________
 - AEVC (10HQ)

 - CARTRIDGE-AVNCS VENT FILTER (2082HM)

 - VALVE-SKIN EXCHANGER OUTLET BYPASS, AVNCS VENT (23HQ)

 - wiring between the AEVC (10HQ) and the skin exchanger-outlet bypass valve (23HQ)

 - wiring from the AEVC (10HQ) to the skin exchanger-outlet bypass valve (23HQ)


 2. Job Set-up Information______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
AMM 21-26-00-710-001  Operational Check of System via MCDU
 AMM 21-26-34-000-001  Removal of the Avionics Equipment Ventilation Computer (AEVC) (10HQ)
 AMM 21-26-43-920-001  Replacement of the Filter Cartridge
 AMM 21-26-55-000-003  Removal of the Avionics Ventilation Skin Exchanger Outlet Bypass Valve (23HQ)
 AMM 21-26-55-400-001  Installation of the Avionics Ventilation Skin Exchanger Inlet Bypass Valve (16HQ)
 AMM 21-26-55-400-003  Installation of the Avionics Ventilation Skin Exchanger Outlet Bypass Valve (23HQ)
 ASM 21-26/03
 3. Fault Confirmation__________________
 A. Test
 (1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) (Ref. AMM TASK 21-26-00-710-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-26-00∞∞∞∞∞∞∞∞∞∞Page 261
 May 01/05R
 CES  4. Fault Isolation


_______________
R **ON A/C 001-049, 051-099, 101-105, 301-399, 401-499,
 A. If the test gives the maintenance message OUTLET BYPASS V 23HQ:
 - make sure that the avionics ventilation filter is not clogged. If necessary, replace it.

 - do a check of the status of the skin exchanger-outlet bypass valve (23HQ) microswitches, between pin A/J and pin A/G and between pin A/M and pin A/K.


 (1) If the status of the microswitch between pins A/J and A/G is equivalent to the status of the microswitch between pins A/M and A/K:

 - replace the VALVE-SKIN EXCHANGER OUTLET BYPASS, AVNCS VENT (23HQ) (Ref. AMM TASK 21-26-55-000-003) and (Ref. AMM TASK 21-26-55-400-003).

 (2) If the status of the microswitch between pins A/J and A/G is not equivalent to the status of the microswitch between pins A/M and A/K:


 - do a check for a ground signal at pin A/U, pin A/G, and pin A/K of the skin exchanger-outlet bypass valve (23HQ) (Ref. ASM 21-26/03).
 (a) If there is no ground signal:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(80)