- if the test gives the maintenance message OUTFLOW VALVE ELEC 2 (52) or,
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 268
Aug 01/02R
CES
(2) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT gives the maintenance message which follows,
- OUTFLOW VALVE ELEC 2 (52) but the test cannot confirm the fault:
- replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2 (referred to as OFV (10HL)) (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
NOTE : The electronic module 2 is connected to the electrical
____ connector 10HL-B.
(3) If the fault continues:
- swap the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(a) If the fault moves with the CPC 2:
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
- replace the CONTROLLER-CABIN PRESSURE 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(b) If the fault does not move with the CPC 2:
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
- do a check and repair the wiring from the: OFV connector (10HL-B) pins R, P, N and M to the CPC 2 connector (12HL-AA) pins 7A, 8A, 9A and 10A (Ref. ASM 21-31/02).
- do a check of the earthing resistance at the return ground connections (Ref. AMM TASK 21-31-00-760-001) on:
1_ the CPC 2 connector 12HL-AC, pin 2 and on,
2_ the electronic module 2 connector 10HL-B, pin J.
NOTE : The resistance value must be smaller than 20 m.ohms.
____
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 269
Aug 01/02R
CES TASK 21-31-00-810-833
Outflow Valve Electronic Module 1 Fault (64), (65), (66), (67), (72), (76),
(83), (87)
1. Possible Causes
_______________
- VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-31-00-710-002 Operational Test of the Pressure Control and Monitoring AMM 21-31-51-000-002 Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) AMM 21-31-51-400-002 Installation of the Outflow Valve (10HL) -Electronics Module 10HL-1 (10HL-2)
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
4. Fault Isolation
_______________
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives one of the maintenance messages which follow, OUTFLOW VALVE ELEC 1 (64), OUTFLOW VALVE ELEC 1 (65), OUTFLOW VALVE ELEC 1 (66), OUTFLOW VALVE ELEC 1 (67), OUTFLOW VALVE ELEC 1 (72), OUTFLOW VALVE ELEC 1 (76), OUTFLOW VALVE ELEC 1 (83) or, OUTFLOW VALVE ELEC 1 (87):
- replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 (referred to as OFV (10HL)) (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
NOTE : The electronic module 1 is connected to the electrical connector
____
10HL-A.
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 270
Aug 01/02R CES
TASK 21-31-00-810-834
Outflow Valve Electronic Module 2 Fault (64), (65), (66), (67), (72), (76),
(83), (87)
1. Possible Causes
_______________
- VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(113)