- SENSOR-PRESSURE (10HB)
- SENSOR-COMPRESSOR PNEUMATIC OVHT (10HM9)
- REHEATER (10HM3)
- VALVE-FLOW CTL (8HB)
- wiring R - PRESSURE SENSOR (23HB1) R - FLOW CONTROL SYSTEM (23HB)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASM 2151S01 AMM 12-33-21-618-001 Pre-conditioning through the HP Ground Connection AMM 21-51-11-000-001 Removal of the Differential Pressure Sensor 9HB
(10HB) AMM 21-51-11-400-001 Installation of the Differential Pressure Sensor 9HB
(10HB) R AMM 21-51-51-000-001 Removal of the Pack Flow-Control Valve R AMM 21-51-51-400-001 Installation of the Pack Flow-Control Valve
AMM 21-51-51-600-001 Scheduled Replacement of a Pack Flow-Control Valve
Trailing-Edge Probe Filter AMM 21-52-31-000-001 Removal of the Reheater 10HM3 (11HM3) AMM 21-52-31-400-001 Installation of the Reheater 10HM3 (11HM3) AMM 21-61-18-000-001 Removal of the Compressor Pneumatic Overheat-Sensor
10HM9 (11HM9)
AMM 21-61-18-400-001 Installation of the Compressor Pneumatic
Overheat-Sensor 10HM9 (11HM9)
AMM 71-00-00-710-003 Engine Automatic Start
AMM 71-00-00-710-028 Engine Shutdown
3. Fault Confirmation
__________________
A. Bleed Air Supply Source from the HP Ground Connection
NOTE : The HP ground supply source must be able to give a pack inlet
____ pressure of 24 PSI minimum. If it can not do this then you must get the bleed air supply from the engines. The work steps which follow show the conditions necessary before you get the minimum pack-inlet pressure.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-51-00∞∞∞∞∞∞∞∞∞∞Page 236
Feb 01/05 CES
(1) Do the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001).
(2) On the AIR COND panel 30VU:
- push the HOT AIR pushbutton switch to the on position (the OFF legend goes off),
- turn the COCKPIT, FWD CABIN and the AFT CABIN temperature selectors to the HOT positions and,
- make sure that the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
(3) On the ECAM BLEED page:
- make sure that the pack 1 inlet pressure indication shows a minimum of 24 PSI.
NOTE : If the indication shows less than 24 PSI you must:
____
- increase the ground pressure supply until the indication shows a minimum of 24 PSI.
B. Start the engines (Ref. AMM TASK 71-00-00-710-003) if necessary.
C. Initial Test Set-up with Engines as Bleed Air Source Supply
(1) On the AIR COND panel 30VU:
- push the HOT AIR pushbutton switch to the on position (the OFF legend goes off),
- turn the COCKPIT, FWD CABIN and the AFT CABIN temperature selectors to the HOT positions and,
- make sure that the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
(2) On the ECAM BLEED page:
- make sure that the pack 1 inlet pressure indication shows a minimum of 24 PSI.
NOTE : If the indication shows less than 24 PSI you must slowly
____ adjust the throttle levers until you get the minimum indication of 24 PSI.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
D. Test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the AIR COND panel 30VU:
- turn the PACK FLOW selector to the LO position and wait for 120 sec.
2. On the AIR COND panel 30VU:
- push the PACK 2 P/BSW and wait for 120 sec.
3. On the AIR COND panel 30VU:
- push the PACK 2 P/BSW.
4. On the AIR COND panel 30VU:
- turn the PACK FLOW selector to the NORM position and wait for 120 sec.
5. On the AIR COND panel 30VU:
- turn the PACK FLOW selector to the HI position and wait for 120 sec.
On the ECAM BLEED page:
- the pack 1 flow indication showsbetween the LO and the 11 oIclockpositions.
On the AIR COND panel 30VU:
- the OFF light of the PACK 2 P/BSWcomes on.
On the ECAM BLEED page:
- the pack 1 flow indication shows between the 1 oIclock and the HI positions.
On the AIR COND panel 30VU: