(e)
Make sure the EICAS message, FLT DATA AQC, is shown on the bottom display.
(f)
Make sure the EICAS message, FLT DATA REC, does not show on the bottom display.
(g)
Open these circuit breakers on the overhead circuit breaker panel, P11, and attach the DO-NOT-CLOSE tags: 1) 11J7, FLIGHT RECORDER AC 2) 11J8, FLIGHT RECORDED DC
(h)
Install the DFDR to the mounting tray (AMM 31-31-02).
(i)
Install the DFDAU to the mounting tray (AMM 31-31-03).
S 865-839-002
(4) Remove the DO-NOT-CLOSE tags and close the P11 panel circuit breakers:
(a)
11J7, FLIGHT RECORDER AC
(b)
11J8, FLIGHT RECORDED DC
(c)
Return the L and R FUEL CONT SWITCHES to the CUTOFF position.
(d)
Set the FRCP switch to the NORM position.
(e)
Remove the DO-NOT CLOSE tags and close the P11 panel circuit breakers: 1) 11D7, ENGINES STBY IGNITION LEFT 1 2) 11D8, ENGINES STBY IGNITION LEFT 2 3) 11D9, ENGINES STBY IGNITION RIGHT 1 4) 11D10, ENGINES STBY IGNITION RIGHT 2 5) 11K9, LEFT ENGINE OIL PRESS
GUN 001-008, 010, 101 POST-EO B531006; ú 31-31-00
GUN 051, 102-999 ú CONFIG 2 ú 07 Page 507 ú Sep 28/01
A
757 MAINTENANCE MANUAL
6) 11K35, RIGHT ENGINE OIL PRESS 7) 11L1, LEFT ENGINE IGN 1 8) 11L28, RIGHT ENGINE IGN 1
(f) Remove the DO-NOT-CLOSE tags and close the P6 panel circuit breakers: 1) 6E1, FUEL VALVES L SPAR 2) 6E2, FUEL VALVES R SPAR
TASK 31-31-00-705-753-002
3. Flight Data Recorder System Test
_________________________________
A. General
(1)
This subject is a system test that test all input parameters that are connected to the flight data recorder.
(2)
A test equipment is necessary to do the flight recorder system test.
B. Equipment
(1)
981-6301-002 Data Signal Display Unit (DSDU)
Alliedsignal Air Transport Avionics
P.O. BOX 97001
15001 NE 36TH ST
Redmond, WA 98073-9701
(2)
A31007-49 Adapter Cable - Tester (recommended)
A31007-30 Adapter Cable - Tester (alternative)
(3)
Portable Tester - Teledyne P/N 2222786
Teledyne Controls
12333 West Olympic Boulevard West
Los Angeles, CA 90064
(4)
A31007-1 Adapter Cable - Tester
(5)
Portable Tester - Teledyne P/N 2229738-1
Teledyne Controls
12333 West Olympic Boulevard West
Los Angeles, CA 90064
(6)
A31007-59 Adapter Cable - Tester
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 仪表 CHAPTER 31 - INSTRUMENTS 1(80)