(2)  
PL1 Ultrasonic Test Set
 Dukane Corporation
 2900 Dukane Drive
 St. Charles, IL 60174
ú
 31-31-02
 ALL  ú ú 04 Page 208 ú May 28/01
A
757 
MAINTENANCE MANUAL
 (3)  
PL3 Ultrasonic Test Set
 Dukane Corporation
 2900 Dukane Drive
 St. Charles, IL 60174
 (4)  
ATS-260 Acoustic Test Set
 Datasonics INC.
 1400 Route 28A
 Cataumet, MA 02534
 B.  Procedure
 S 712-012
 (1)  If you have a 42A12C test set, do this test of the ULB:
 (a)  
Put the test set approximately 3 feet from the ULB.
 (b)  
Set the ON-OFF-GAIN control on the test set to the middle position. 1) Make sure you hear sounds through the earphone on the test
set.
 (c)  
Set the TUNING CONTROL to 37|1 kHZ.
 (d)  
Set the INPUT SELECTOR switch to the INT position.
 (e)  
Make sure the test set operates correctly.
 1)  Shake a set of keys or some coins in front of the microphone to make sure it operates.
 NOTE: This will supply ultrasonic sound.
____
 a)  Make sure you hear sounds through the test set earphone.
 (f)  Use any kind of tape to attach a piece of flexible metal conductor to the ULB case and the center of the water switch.
 NOTE: This will make a short circuit from the center of
____ the water switch to the outer part of the ULB.
 1)  Make sure you hear a pulsed tone at 1-second intervals.
 (g)  
Remove the flexible metal conductor from the ULB case and center of the water switch. 1) Make sure you do not hear a pulsed tone.
 (h)  
Set the ON-OFF-GAIN control switch to the OFF position.
 S 712-013
 (2)  If you have a PL1 test set, do this test of the ULB:
 (a)  Use tape to attach a piece of flexible metal conductor to the ULB case and the center of the water switch.
 NOTE: This will make a short circuit from the center of
____ the water switch to the outer part of the ULB.
  ú
 31-31-02
 ALL  ú ú 05 Page 209 ú May 28/01
A 
757 MAINTENANCE MANUAL
 (b)  
Put the end of the test set against the ULB, approximately one inch from the water switch.
 