E. Procedure
 S 034-006
 (1)  
Disconnect the control column position transducer electrical connector.
S 034-007
 (2)  
Remove the screw from the crank arm assembly that holds the serrated shaft of the transducer.
S 034-008
 (3)  
Remove the screw from the collar bracket that holds the transducer in position.
S 024-009
 (4)  
Remove the transducer from the collar bracket.
 TASK 31-31-08-404-034
 3.  Control Column Position Transducer Installation (Fig. 401)_______________________________________________
 A. Equipment
 (1)  981-6301-002 Data Signal Display Unit (DSDU)
 Alliedsignal Air Transport Avionics
 P.O. BOX 97001
 15001 NE 36TH ST
 Redmond, WA 98073-9701
 
 GUN 001-008, 010, 101 POST-EO B531006;  ú 31-31-08
 GUN 051, 102-999  ú ú 13 Page 403 ú Sep 28/01
A 
757 
MAINTENANCE MANUAL
 (2)  
A31007-49 Adapter Cable - Tester (recommended)
 A31007-30 Adapter Cable - Tester (alternative)
 (3)  
Portable Tester - Teledyne P/N 2222786
 Teledyne Controls
 12333 West Olympic Boulevard West
 Los Angeles, CA 90064
 (4)  
A31007-1 Adapter Cable - Tester
 (5)  
Portable Tester - Teledyne P/N 2229738-1
 Teledyne Controls
 12333 West Olympic Boulevard West
 Los Angeles, CA 90064
 (6)  
A31007-59 Adapter Cable - Tester
 (7)  
964-0446-001 Hand Held Download Unit (HHDLU)
 27914 Allied-Signal Inc., DBA Allied-Signal Aerospace
 2100 Northwest 62nd Street
 Fort Lauderdale, FL 33309
 (a)  AIRPLANES WITH FDR P/N 980-4700-042;
 The HHDLU must have mod 1 completed.
 (8)  
704-2567-001 Adapter Cable - Tester
 (9)  
Multi-Purpose AIDS Display Units - AACO Inc.
 FAA-0032-001
 AACO Inc.
 5011 Barton Place
 Seattle, WA 98118
 (10)
 EGA-005-001, Adapter Cable - MADU
 B. References
 (1)  
AMM 20-10-23/401, Lockwire
 (2)  
AMM 20-10-24/201, Rig Pins
 (3)  
AMM 24-22-00/201, Eletrical Power Control
 (4)  
AMM 29-11-00/201, Main (Left, Right, and Center) Hydraulic Systems
 C. Access
 (1)  Location Zone
 113 Area forward of NLG wheel well (left)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 仪表 CHAPTER 31 - INSTRUMENTS 1(141)