704-2567-001 Adapter Cable - Tester

 (10)
 Multi-Purpose AIDS Display Units - AACO Inc. FAA-0032-001 AACO Inc. 5011 Barton Place Seattle, WA 98118

 (11)
 EGA-0005-001, Adapter Cable - MADU


 B. References
 (1)  AMM 24-22-00/201, Electrical Power
  ú

 31-31-05
 ALL  ú ú 02 Page 403 ú Jan 28/02

A
757
MAINTENANCE MANUAL

 (2)  
AMM 32-00-15/201, Landing Gear Door Ground Operation and Locking Procedure

 (3)  
AMM 32-00-20/201, Landing Gear Downlocks


 C. Access ú (1) Location Zone ú 731 Main Landing Gear ú
 D. Procedure
 S 864-009
 (1) Make sure these circuit breakers on the P11 panel are open:
 (a)  
11J7, FLIGHT RECORDER AC

 (b)  
11J8, FLIGHT RECORDER DC


 S 424-010
 (2)  
Install the accelerometer to the mounting bracket.

 S 434-011

 (3)  
Connect the electrical cable to the accelerometer.


 S 494-033
 WARNING:_______OBEY THE INSTALLATION PROCEDURE FOR THE DOOR LOCKS. THE DOORS OPEN AND CLOSE QUICKLY. THE MOVEMENT OF THE DOORS CAN CAUSE INJURIES TO PERSONS AND DAMAGE TO EQUIPMENT.
 (4)  Remove the door locks from the landing gear doors and close the doors (AMM 32-00-15/201).
 E. Accelerometer Test
 S 864-083
 (1)  
If you use test equipment other than the hand-held download unit (HHDLU), install the tester to the test connector at the right side panel, P61.

 S 864-084

 (2)  
If you use the hand-held download unit (HHDLU), attach the HHDLU to the test connector at the front side of the flight data recorder.


 NOTE: To get access to the FDR, open the lower ceiling panel No. 1
____ above the aft galley (AMM 25-22-02/401). The HHDLU can only be connected to the AlliedSignal flight data recorder (FDR).
 S 864-015
 (3)  
Remove DO-NOT-CLOSE tags and close the P11 panel circuit breakers:

 (a)  
11J7, FLIGHT RECORDER AC

 (b)  
11J8, FLIGHT RECORDER DC

 

 (4)  
Supply electrical power (AMM 24-22-00/201).


 S 864-016
  ú

 31-31-05
 ALL  ú ú 02.1 Page 404 ú Sep 28/02

A
757
MAINTENANCE MANUAL

 S 864-085
 (5)  With the Data Signal Display Unit (DSDU), set the control switches on the tester as follows:
 (a)  
Set the power switch to the ON position.

 (b)  
Set the INPUT switch to the ARINC INPUT DATA position.

 (c)  
 
中国航空网 www.aero.cn