GUN 206-999 ú
31-31-02
ú ú 14 Page 202 ú Dec 20/94
E04812
A
757
MAINTENANCE MANUAL
DIGITAL FLIGHT DATA RECORDER
WATER SWITCH
UNDERWATER LOCATOR BEACON
UNDERWATER LOCATOR BEACON
Underwater Locator Beacon Installation
Figure 201 (Sheet 2)
GUN 001-205 ú
31-31-02
ú ú 15 Page 203 ú Dec 20/94
E04664
A
757 MAINTENANCE MANUAL
(d) Keep the two screws and the clamp.
TASK 31-31-02-962-044
3. FLIGHT DATA RECORDERS WITH DUKANE ULBs; Underwater Locator Beacon Battery Replacement (Fig. 202)_____________________________________________
A. General
(1) Do not replace the battery in the DK100 underwater locator beacon (ULB). On or before the expired date, send the DK100 to the manufacturer for servicing.
B. Equipment
(1)
810-325 Spanner Wrench
Dukane Corporation
2900 Dukane Drive
St. Charles, IL 60174
(2)
Split Radiator Hose
1-1/4-inch diameter, 5 inches in length
C. Consumable Materials
(1)
D00318 Lubricant, Dukane 810-346
(2)
G02440 Battery, Dukane 810-2007K
(3)
G00751 O-ring, Dukane 810-342
(4)
G01523 Lubricated O-ring, Datasonics 2-022
D. Removal Procedure
S 512-055
WARNING:_______DO NOT REMOVE THE BATTERY FROM THE DK100 ULB. DO NOT CAUSE DAMAGE TO THE DK100 ULB. DO NOT DISCARD THE DK100 ULB. THE MANUFACTURER HAS A REPLACEMENT PROGRAM FOR EXPIRED ULBs. ON OR BEFORE THE EXPIRED DATE, SEND THE DK100 ULB TO THE MANUFACTURER FOR SERVICING. THE BATTERY CONTAINS DANGEROUS CHEMICAL MATERIALS WHICH CAN CAUSE INJURIES TO PERSONNEL.
(1)
If you have a DK100 ULB, send the ULB to the manufacturer for servicing.
(2)
If you do not have a DK100 ULB, remove the ULB battery:
S 022-011
ú
31-31-02
ALL ú ú 03 Page 204 ú May 28/01
A
757
MAINTENANCE MANUAL
ULB DISASSEMBLY (BATTERY ACCESS)
SHOCK
BATTERY INSTALLATION
Underwater Locator Beacon Battery Installation
Figure 202
ú
31-31-02
ALL ú ú 02 Page 205 ú Mar 20/94
E05409
A
757 MAINTENANCE MANUAL
CAUTION: DO NOT HOLD THE UNDERWATER LOCATOR BEACON WITH A VISE.
_______ THIS CAN CAUSE DAMAGE TO THE UNDERWATER LOCATOR BEACON.
(a)
Hold the ULB body with a split radiator hose.