 NOTE: Do not apply more than 25 pound-inches (2.8 newton meters)
____ of torque. Use only your hand to turn the shutoff valve.
 S 433-029
 (16) Install the lockwire to hold the valve in this position.
 NOTE: Use the 0.020 inch diameter copper lockwire
____
 (AMM 20-10-23/401).

 S 793-031
 (17)
 Do a leakage check on the oxygen cylinder couplings with the leak detection compound.

 S 793-032

 (18)
 Remove the leak detection compound with a clean cloth immediately after you do the check.

 S 213-033

 (19)
 Immediately compare the pressure shown on the status page of the EICAS and the pressure shown on the cylinder gage.


 NOTE: The difference of the pressure values must be less
____
 than 100 PSI.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-15-08
 ALL  ú ú 04 Page 314 ú May 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757 MAINTENANCE MANUAL
 S 433-034
 (20)
 For oxygen cylinders with a cap held by a chain, install the lockwire on the cap to decrease its movement.

 S 413-035

 (21)
 Close the access door for the oxygen cylinder.

 S 863-036

 (22)
 Remove the electrical power if it is not necessary
 (AMM 24-22-00/201).

 

 TASK 12-15-08-603-157
 3.  GUN 004-007; Passenger Oxygen System Servicing (Cylinder Replacement) (Fig. 303, Fig. 304)
________________________________________________________
 NOTE: This procedure is used when an unserviceable oxygen cylinder is
____
 replaced. Normal servicing is by the external fill method.

 A.  General
 (1)  
The passenger oxygen cylinders are found in the aft cargo compartment.

 (2)  
For cylinders with less than 5 psig (34.5 kPa) you must replace the cylinder with one that is fully serviceable. Cylinders with less than 5 psig (34.5 kPa) usually contain too much fluid. Use this procedure to replace the unserviceable oxygen cylinder.

 (3)  
Read and obey the Passenger Oxygen System - Maintenance Practices before you do the servicing (AMM 35-21-00/201).


 B.  Equipment
 (1)  
Caps and Plugs - Clean, Packaged (for oxygen
 ports and open lines)


 (2)  
Oxygen Cylinders - Fully Charged and Serviceable

 (3)  
Spanner Wrench - Commercially Available


 C.  Consumable Materials
 (1)  G00092 Oxygen System Leak Detection
 Compound - Sherlock CG Type 1

 D.  References
 (1)  
AMM 20-11-00/201, Standard Torque Values

 (2)  
AMM 20-41-00/201, Static Grounding

 (3)  
AMM 24-22-00/201, Electrical Power - Control

 (4)  
AMM 35-21-00/201, Passenger Oxygen System


 E.  Access
 (1)  Location Zones
 161/162 Bulk Cargo Compartment

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-15-08
 ALL  ú ú 03 Page 315 ú May 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 F. Procedure - Remove the Passenger Oxygen Cylinder
 S 913-105
 WARNING: OBEY THE MAINTENANCE PRACTICES GIVEN FOR THE PASSENGER OXYGEN
_______ SYSTEM. IF YOU DO NOT OBEY THEM, A FIRE OR AN EXPLOSION CAN OCCUR.
 (1)  
Read and obey the Passenger Oxygen System - Maintenance
 Practices (AMM 35-21-00/201).


 S 493-106

 (2)
Make sure the airplane is grounded correctly (AMM 20-41-01/201).

 S 863-159

 (3)  
Open these circuit breakers and install DO-NOT-CLOSE tags:

 (a)  
On the overhead circuit breaker panel, P11:
 1) 11S33, OXYGEN PRESS
 2) 11S32, PASS OXY PRESS


 (b)  
On the APU/EXT power panel, P34:
 1) 34B2, PASS OXY PRESS IND

 

 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 SERVICING 1(70)