 S 163-032

 (16)
 Remove the hydraulic fluid from the suction hose with a rag.

 S 423-033

 (17)
 Put the suction hose into the pump handle.

 S 863-034

 (18)
 Remove electrical power if it is not necessary (AMM 24-22-00/201).

 S 413-039

 (19)
 Close the access panel, 197KL, for the central hydraulic service center (AMM 06-41-00/201).


 TASK 12-12-01-613-036
 4.  Fill the Hydraulic Reservoir - Pressure Procedure_________________________________________________
 A. Equipment
 (1)  Hydraulic Ground Service Cart, with Hydraulic Fluid, Fire-Resistant - BMS 3-11
 B. References
 (1)  
AMM 06-41-00/201, Fuselage Access Doors and Panels.

 (2)  
AMM 24-22-00/201, Electrical Power - Control

 (3)  
AMM 29-11-00/201, Main (Left, Right, and Center) Hydraulic Systems


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-12-01
 ALL  ú ú 01 Page 308 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 C. Consumable Materials
 (1)  D00153 Hydraulic Fluid, Fire-Resistant -BMS 3-11

 D. Access
 (1)  
Location Zones
 197 Wing to Body - Aft Lower Half (Left)


 (2)  
Access Panels
 197KL Central Hydraulic Service Center

 

 E. Procedure (Fig. 301)
 S 863-037
 (1)  
Supply electrical power (AMM 24-22-00/201).

 S 013-038

 (2)  
Open the access door, 197KL, for the central hydraulic service center (AMM 06-41-00/201).

 S 863-040

 (3)  
Do these steps before you fill the reservoir in the right hydraulic system:


 (a)  Make sure the pressure gage on the brake accumulator, in the aft left wing-to-body fairing, shows a minimum of 2500 psi.
 CAUTION: YOU MUST HAVE FLUID IN THE RIGHT SYSTEM RESERVOIR, BEFORE
_______ YOU OPERATE THE HYDRAULIC PUMPS OR YOU MUST PRESSURIZE THE RIGHT SYSTEM WITH A HYDRAULIC SERVICE CART. IF YOU OPERATE THE HYDRAULIC PUMPS WITHOUT SUFFICIENT FLUID IN THE RESERVOIR, YOU CAN CAUSE DAMAGE TO THE PUMPS.
 (b)  
If the pressure gage does not show a minimum of 2500 psi, pressurize the right hydraulic system (AMM 29-11-00/201).

 (c)  
Remove hydraulic power, after the right hydraulic system pressurizes the brake accumulator to a minimum of 2500 psi (AMM 29-11-00/201).


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 12-12-01
 ALL  ú ú 01 Page 309 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL

 WARNING: USE THE PROCEDURE IN AMM 32-00-15 TO REMOVE THE DOOR
_______ LOCKS. THE DOORS OPEN AND CLOSE QUICKLY AND CAN CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (d)  For the left or right system, remove the door locks from the landing gear doors and close the doors (AMM 32-00-15/201).
 S 493-052
 CAUTION: USE CLEAN HYDRAULIC FLUID, BMS 3-11, AND CLEAN EQUIPMENT TO
_______ FILL THE HYDRAULIC SYSTEM RESERVOIRS. IF YOU DO NOT USE CLEAN HYDRAULIC FLUID AND EQUIPMENT, CONTAMINATION OF THE HYDRAULIC SYSTEM CAN OCCUR.
 ALL CURRENTLY QUALIFIED BMS 3-11, TYPE IV HYDRAULIC FLUIDS ARE INTERCHANGEABLE AND INTERMIXABLE IN ANY PROPORTION.
 (4)  Connect the ground service cart to the pressure fill connection.
 S 613-051
 WARNING: BE CAREFUL TO NOT FILL THE RESERVOIR TO MORE THAN THE NECESSARY
_______ LEVEL. IF YOU PUT TOO MUCH FLUID IN THE RESERVOIRS, THE FLUID CAN GO INTO THE DUCTS OF THE PNEUMATIC SYSTEM AND THE AIR CONDITIONING PACKS. THIS CAN CAUSE SMOKE AND DANGEROUS FUMES TO GO INTO THE FLIGHT COMPARTMENT AND THE PASSENGER CABIN. IF CONTAMINATION OF THE PNEUMATIC SYSTEM OCCURS AGAIN AND AGAIN, IT CAN CAUSE DAMAGE TO THE TITANIUM DUCTS.
 (5)  Do these steps for each hydraulic reservoir you will fill:
 (a)  Put the reservoir fill valve to the position (L, R, or C) for the hydraulic system in which you will fill the reservoir.
 