- do an operational test of the engine interface unit and see if the "NO ZONE CONT DATA" message is shown (Ref. AMM TASK 73-25-34-710-043).
(a) If the message is shown:
- replace the CONT-ZONE TEMPERATURE (8HK) (Ref. AMM TASK 21-63-34-000-001) and (Ref. AMM TASK 21-63-34-400-001).
(b) If the message is not shown:
- replace the EIU-1 (1KS1) (Ref. AMM TASK 73-25-34-000-040) and (Ref. AMM TASK 73-25-34-400-040).
(3) If the fault continues:
- replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
B. Do the test given in Para. 3.A.
F 『 EEFF : ALL E ∞∞73-25-00∞∞∞∞∞∞∞∞∞∞Page A209
E E Aug 01/05 ERE
ECES TASK 73-25-00-810-925
F 『
E C F M E
E E
E 56 E
E E
Loss of the Zone Controller Data on the ARINC Bus from the EIU to the FADEC on Engine 2
1. Possible Causes
_______________
- EIU-2 (1KS2)
- harness J3 from the EIU-2 (1KS2) to the ECU (4000KS)
- CONT-ZONE TEMPERATURE (8HK)
- ECU (4000KS)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-63-34-000-001 Removal of the Zone Controller (8HK)
AMM 21-63-34-400-001 Installation of the Zone Controller (8HK)
AMM 73-21-60-000-001 Removal of the Electronic Control Unit (ECU)(4000KS)
AMM 73-21-60-400-001 Installation of the Electronic Control Unit
(ECU)(4000KS) AMM 73-25-34-000-040 Removal of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-25-34-400-040 Installation of the Engine Interface Unit (EIU)
(1KS1,1KS2) AMM 73-25-34-710-043 Operational Test of the Engine Interface Unit AMM 73-29-00-710-040 Operational Test of the FADEC on the Ground (with
Engine non Motoring) ASM 73-25/06
3. Fault Confirmation
__________________
A. Do the operational test of the FADEC 2B on the ground (with engine non motoring) (Ref. AMM TASK 73-29-00-710-040).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ZC, EIU (ECSD), J3:
- do a check for open or short to ground at the pins AB/5A, 5C to pins J3/22, 23 of the harness J3 from the EIU-2 (1KS2) to the ECU (4000KS) (Ref. ASM 73-25/06).
(1) If the wiring is not correct:
- repair the above harness J3.
F 『 EEFF : ALL E ∞∞73-25-00∞∞∞∞∞∞∞∞∞∞Page A210
E E Aug 01/05 ERE
ECES E 56 E E E (2) If the wiring is correct:
F 『
E C F M E
E E
- do an operational test of the engine interface unit and see if "NO ZONE CONT DATA" message is shown (Ref. AMM TASK 73-25-34-710-043).
(a) If the message is shown:
- replace the CONT-ZONE TEMPERATURE (8HK) (Ref. AMM TASK 21-63-34-000-001) and (Ref. AMM TASK 21-63-34-400-001).
(b) If the message is not shown:
- replace the EIU-2 (1KS2) (Ref. AMM TASK 73-25-34-000-040) and (Ref. AMM TASK 73-25-34-400-040).
(3) If the fault continues:
- replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
B. Do the test given in Para. 3.A.
F 『 EEFF : ALL E ∞∞73-25-00∞∞∞∞∞∞∞∞∞∞Page A211
E E Aug 01/05 ERE
ECES TASK 73-25-00-810-926
F 『
E C F M E
E E
E 56 E