 a If the resistance values are in the specified limits:
_
 - replace the ECU (4000KS), (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
 b If the resistance values are out of the specified limits:
_
 - replace the harness J8, (Ref. AMM TASK 73-21-50-000-041) and (Ref. AMM TASK 73-21-50-400-041).
 B. Do the test given in Para. 3.A.(1).
 (1) No additional maintenance action is required if the fault is not confirmed.

 (2) Repeat the fault isolation procedure if the fault continues.


 F 『 EEFF : ALL E ∞∞73-29-00∞∞∞∞∞∞∞∞∞∞Page A216
 E E May 01/05 ERE
ECES

 F 『
 E C F M E
 E E
 E 56 E
 E E


 TASK 73-29-00-810-866
 Loss of the Feedback Signal from the FMV Resolver through the Channel A on Engine 2
 1. Possible Causes
_______________
 - Hydromechanical Unit (HMU)

 - harness J7

 - ECU (4000KS)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 73-21-10-000-002 Removal of the Hydromechanical Unit (HMU) AMM 73-21-10-400-002 Installation of the Hydromechanical Unit (HMU) AMM 73-21-50-000-040 Removal of the HJ7 Harness AMM 73-21-50-210-002 Visual Inspection of the Wiring Harnesses AMM 73-21-50-400-040 Installation of the HJ7 Harness AMM 73-21-60-000-001 Removal of the Electronic Control Unit (ECU)(4000KS) AMM 73-21-60-400-001 Installation of the Electronic Control Unit
 (ECU)(4000KS) AMM 73-29-00-710-040 Operational Test of the FADEC on the Ground (with Engine non Motoring)
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the FADEC 2A on the ground (with engine non - motoring) (Ref. AMM TASK 73-29-00-710-040).
 4. Fault Isolation
_______________
 A. Do this procedure:
 NOTE : This fault is generated if channel A FMV resolver signal is out of
____ range, invalid or the signal disagrees with channel B.
 (1) If the test does not give the maintenance message J7, HMU(FMVRES), ECU:
 - replace the Hydromechanical Unit (HMU), (Ref. AMM TASK 73-21-10-000-002) and (Ref. AMM TASK 73-21-10-400-002).

 - Visually examine the J7 harness connector for damaged pins, contamination and fuel wetting (Ref. AMM TASK 73-21-50-210-002).


 F 『 EEFF : ALL E ∞∞73-29-00∞∞∞∞∞∞∞∞∞∞Page A217
 E E May 01/05 ERE ECES

 F 『
 E C F M E
 E E
 E 56 E
 E E
 (a) If damage on a connector is found:

 - Replace or repair as required.
 (b) If fuel wetting is found:

 - replace the harness J7, (Ref. AMM TASK 73-21-50-000-040) and (Ref. AMM TASK 73-21-50-400-040).

 (c) If nothing is found:


 - No further action is required.
 (2) If the test does not give the maintenance message J7, HMU(FMVRES), ECU, but is repetitive after the troubleshooting per step 4.A.(1) has been fully done:

 - replace the harness J7, (Ref. AMM TASK 73-21-50-000-040) and (Ref. AMM TASK 73-21-50-400-040).
 (a) If the fault continues during the subsequent flights:
 - replace the ECU (4000KS), (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).

 (3) If the test gives the maintenance message J7, HMU(FMVRES), ECU:


 - disconnect the J7 harness from the HMU receptacle (HMU-A) (located in the left core compartment) and visually examine the J7 harness connector and the HMU receptacle for damaged pins, contamination and fuel wetting (Ref. AMM TASK 73-21-50-210-002).
 (a) If damage on a connector is found:

 - Replace or repair as required.

 (b) If fuel wetting is found:

 - replace the harness J7, (Ref. AMM TASK 73-21-50-000-040) and (Ref. AMM TASK 73-21-50-400-040).

 (c) If nothing is found:


 - Do an electrical resistance test through the HMU receptacle between: . pins 16 and 34 (34 to 46 or 85 to 150 Ohms) . pins 35 and 36 (21 to 29 or 44 to 76 Ohms) . pins 18 and 37 (21 to 29 or 44 to 76 Ohms) . pins 16 and 17 (> 10 Megohms) . pins 35 and 17 (> 10 Megohms) . pins 18 and 17 (> 10 Megohms) . pin 16 and the ground (> 10 Megohms) . pin 35 and the ground (> 10 Megohms) . pin 18 and the ground (> 10 Megohms).
 1 If the resistance values are out of the specified limits:
 
中国航空网 www.aero.cn