- repair the above wiring.
(b) If the wiring is correct:
- replace the FCU (2CA) (Ref. AMM TASK 22-81-12-000-001) and (Ref. AMM TASK 22-81-12-400-001).
(3) If the fault continues:
- replace the FMGC (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(4) If the fault continues:
- replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
B. Do the test given in Para. 3.A.
F 『 EEFF : ALL E ∞∞73-25-00∞∞∞∞∞∞∞∞∞∞Page 261
E E Feb 01/05 ERE
ECES
F 『
E C F M E
E E
E 56 E
E E
TASK 73-25-00-810-891
Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 1
1. Possible Causes
_______________
- EIU-1 (1KS1)
- harness J3 between the EIU (1KS1) and the ECU (4000KS)
- CONT-ZONE TEMPERATURE (8HK)
- ECU (4000KS)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-63-34-000-001 Removal of the Zone Controller (8HK)
AMM 21-63-34-400-001 Installation of the Zone Controller (8HK)
AMM 73-21-60-000-001 Removal of the Electronic Control Unit (ECU)(4000KS)
AMM 73-21-60-400-001 Installation of the Electronic Control Unit
(ECU)(4000KS) AMM 73-25-34-000-040 Removal of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-25-34-400-040 Installation of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-29-00-710-040 Operational Test of the FADEC on the Ground (with Engine non Motoring) ASM 73-25/06
3. Fault Confirmation
__________________
A. Test Do the operational test of the FADEC 1A on the ground (with engine non motoring) (Ref. AMM TASK 73-29-00-710-040).
4. Fault Isolation
_______________
A. If the test gives the maintenance message FCU, EIU (034), J3:
- do a check for open or short to ground of the harness J3 between the EIU (1KS1) and the ECU (4000KS) pins AB/5A, 5C to pins J3/22, 23 (Ref. ASM 73-25/06).
(1) If the wiring is not correct:
- repair the above wiring.
(2) If the wiring is correct:
- replace the EIU-1 (1KS1) (Ref. AMM TASK 73-25-34-000-040) and (Ref. AMM TASK 73-25-34-400-040).
F 『 EEFF : ALL E ∞∞73-25-00∞∞∞∞∞∞∞∞∞∞Page 262
E E Feb 01/05 E
RE ECES
E F 『 E C F M E E E E 56 E E E (3) If the fault continues:
- replace the CONT-ZONE TEMPERATURE (8HK) (Ref. AMM TASK 21-63-34-000-001) and (Ref. AMM TASK 21-63-34-400-001).
(4) If the fault continues:
- replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
B. Do the test given in Para. 3.A.
F 『 EEFF : ALL E ∞∞73-25-00∞∞∞∞∞∞∞∞∞∞Page 263
E E Feb 01/00 ERE
ECES
F 『
E C F M E
E E
E 56 E
E E
TASK 73-25-00-810-892
Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 2
1. Possible Causes
_______________
- EIU-2 (1KS2)
- harness J3 between the EIU-2 (1KS2) and the ECU (4000KS)
- CONT-ZONE TEMPERATURE (8HK)
- ECU (4000KS)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-63-34-000-001 Removal of the Zone Controller (8HK)
AMM 21-63-34-400-001 Installation of the Zone Controller (8HK)
AMM 73-21-60-000-001 Removal of the Electronic Control Unit (ECU)(4000KS)
AMM 73-21-60-400-001 Installation of the Electronic Control Unit
(ECU)(4000KS) AMM 73-25-34-000-040 Removal of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-25-34-400-040 Installation of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-29-00-710-040 Operational Test of the FADEC on the ground (with Engine Motoring) ASM 73-25/06
3. Fault Confirmation
__________________