 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞52-35-00∞∞∞∞∞∞∞∞∞∞Page 205
 Feb 01/98 CES b If there is 28 VDC:


 a_ If there is 28 VDC:
 - replace the SW ACTUATOR 2 FWD CARGO DOOR (2503MJ) (Ref.
 AMM TASK 52-36-18-000-002).

_
 - do a check and repair the wiring between: the SW ACTUATOR 2 FWD CARGO DOOR (2503MJ) connector A/B and INDICATOR LIGHT FWD CARGO DOOR (9MJ) connector 2 (Ref. ASM 52-35/01) or the SW ACTUATOR 2 FWD CARGO DOOR (2503MJ) connector A/C and GND (Ref. ASM 52-35/01).
 B. Do the test as given in Para. 3.A. to make sure that the operation is correct.
 5. Close-up
________
 A. Put the system back to the serviceable condition.


 CARGO COMPARTMENT DOOR HYDRAULIC SYSTEM - FAULT ISOLATION PROCEDURES
____________________________________________________________________
 TASK 52-36-00-810-806
 FWD and AFT Cargo Compartment Doors do not operate in the Normal Mode
 1. Possible Causes
_______________
 - LIGHT-AFT DOOR OPEN AND LOCKED (8MJ)

 - LIGHT-FWD DOOR OPEN AND LOCKED (9MJ)


 - RELAY-SCCB PWR SPLY (3811GX) R - RELAY-TIME (6MJ) R - RELAY-L/G POSITION, SYS 2 (12GB) R - LGCIU-2 (5GA2)
 - RELAY-PTU VALVE (1803GL)

 - RELAY-GND INTERNAL LEAK TEST (1885GP)

 - TIME RELAY (3816GX)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
52-36-00-810-801  Fault during the Opening Procedure of the FWD
 Cargo-Compartment Door

 52-36-00-810-802  Fault during the Opening Procedure of the AFT
 Cargo-Compartment Door

 52-36-00-810-803  Fault during the Closing Procedure of the FWD
 Cargo-Compartment Door

 52-36-00-810-804  Fault during the Closing Procedure of the AFT
 Cargo-Compartment Door

 AMM 52-30-00-860-001  Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump
 AMM 52-35-12-400-001  Installation of the Indicator Light 9MJ
 3. Fault Confirmation
__________________
 A. Aircraft Maintenance Configuration
 (1) Operate the FWD or AFT cargo compartment door (referred to as cargo door) as required in the normal mode (Ref. AMM TASK 52-30-00-860-001).
 NOTE : Make sure that a second person does not operate the other
____
 cargo door.

 

 (2) Operate the AFT or FWD cargo door as required in the normal mode (Ref. AMM TASK 52-30-00-860-001).
 NOTE : Make sure that a second person does not operate the other
____
 cargo door.

 4. Fault Isolation
_______________
 A. If the fault confirmation gives that both cargo doors do not operate in R normal mode:
 - do a check of the CB (1MJ) to make sure that it is closed.
 (1) If the CB (1MJ) is opened :
 - do a check of the LIGHT-AFT DOOR OPEN AND LOCKED (8MJ) and LIGHT-FWD DOOR OPEN AND LOCKED (9MJ) to make sure that they are satisfactory.
 NOTE : If necessary, replace the applicable light (Ref. AMM TASK 52-
____
 35-12-400-001).

 (2) If the CB (1MJ) is closed :
 - put the YELLOW ELEC PUMP P/SW (3804GX) on the cockpit panel 40VU in the ON position and examine if the ELEC PUMP-Y (3075GX) operates.
 NOTE : Make sure that the selector of the applicable manual selector
____ valve is operated during the fault isolation procedure.
 (3) If the ELEC PUMP-Y (3075GX) does not operate:

 - do a trouble shooting of the ELEC PUMP-Y (3075GX) (Ref. TASK 29-24-00-810-801).

 (4) If the ELEC PUMP-Y (3075GX) operates:

 - push the YELLOW ELEC PUMP P/SW (3804GX) so that the ELEC PUMP-Y (3075GX) does not more operate

 - do a check for 28 VDC between the RELAY-SCCB PWR SPLY (3811GX) connector A/A2 and GND (Ref. ASM 29-24/01).


 (a) If there is 28 VDC:

 - do a check and repair wiring between the RELAY-SCCB PWR SPLY (3811GX) connector A/A2 and the DET-PHASE UNBALANCE, Y ELEC PUMP (3808GX) connector A/F.

 (b) If there is no 28 VDC:

 


 - do a check for continuity between the RELAY-SCCB PWR SPLY (3811GX) connectors A/A1 and A/A2 (Ref. ASM 29-24/01).
 1 If there is no continuity:
_
 - do a check for 28 VDC between the RELAY-SCCB PWR SPLY (3811GX) connector A/X1 and GND (Ref. ASM 29-24/01).
 