4. Fault Isolation
_______________
 A. If the test gives the maintenance meassage DOOR BOTTLE EXIT L
 - open the LH AFT emergency exit door (Ref. AMM TASK 52-22-00-010-001) and look at the pressure indicator of the ACTUATOR EMERGENCY EXIT (1602WM).
 (1) If the pressure indicator shows less than 1783 psi (122.9335 bar):
 - charge the ACTUATOR EMERGENCY EXIT (1602WM) (Ref. AMM TASK 52-22-00-614-002).
 (a) If the pressure decreases again:
 - do the trouble shooting of the ACTUATOR EMERGENCY EXIT (1602WM) (Ref. TASK 52-22-00-810-815).
(2) If the fault continues:
 - do a check for continuity between: the pins A and B of the CYL-DAMPER & EMER OPER, AFT EMER EXIT DR L (360RH7) (Ref. ASM 23-73/10).
 (a) If there is continuity:
 - replace the ACTUATOR EMERGENCY EXIT (1602WM) (Ref. AMM TASK 52-22-14-000-001).
(3) If the fault the continues:
- do a check and repair as necessary the aircraft wiring between: the pin C/38 of the DEU-B (300RH4) and the receptacle pin B of the CYL-DAMPER & EMER OPER, AFT EMER EXIT DR L (360RH7) (Ref. ASM 23-73/10). the pin A of the CYL-DAMPER & EMER OPER, AFT EMER EXIT DR L (360RH7) and GND (Ref. ASM 23-73/10).
(4) If the fault continues:
 - do a trouble shooting procedure of the DEU-B (300RH4) (Ref. TASK 23-73-00-810-827).
 B. Do the test as given in para. 3.
TASK 52-22-00-810-809
 Door Bottle Procedure (RH AFT Emergency Exit) - Fault
 1. Possible Causes_______________
 - ACTUATOR EMERGENCY EXIT (1603WM)
- DEU-B (300RH4)
- CYL-DAMPER & EMER OPER, AFT EMER EXIT DR R (360RH8)
- aircraft wiring
 2. Job Set-up Information______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
23-73-00-810-827  DEU-B - Fault in DEU-B 300RHx with connected Systems/Devices
 52-22-00-810-815  Pressure Leakage on the Door Damper and Emergency Operation Cylinder
 AMM 23-73-00-740-005  BITE Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
 AMM 52-22-00-010-001  Opening of the Emergency Exit Doors from the Passenger Compartment
 AMM 52-22-00-614-002  Charging of the Door Damper and Emergency Operation Cylinders (1600WM, 1601WM, 1602WM, 1603WM) at the Emergency Exit Doors
 AMM 52-22-14-000-001  Removal of the Door Damper and Emergency Operation Cylinder
 ASM 23-73/10
 ASM 23-73/11
 3. Fault Confirmation__________________
 A. Do the bite test of the cabin intercommunication data system through the CFDS (Ref. AMM TASK 23-73-00-740-005).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance meassage DOOR BOTTLE EXIT R
 - open the RH AFT emergency exit door (Ref. AMM TASK 52-22-00-010-001) and look at the pressure indicator of the ACTUATOR EMERGENCY EXIT (1603WM).
 (1) If the pressure indicator shows less than 1783 psi (122.9335 bar):
 - charge the ACTUATOR EMERGENCY EXIT (1603WM) (Ref. AMM TASK 52-22-00-614-002).
 (a) If the pressure decreases again:
 - do a trouble shooting of the ACTUATOR EMERGENCY EXIT (1603WM) (Ref. TASK 52-22-00-810-815).
(2) If the fault continues:
 - do a check for continuity between: the pins A and B of the CYL-DAMPER & EMER OPER, AFT EMER EXIT DR R (360RH8) (Ref. ASM 23-73/11).
 (a) If there is continuity:
 - replace the ACTUATOR EMERGENCY EXIT (1603WM) (Ref. AMM TASK 52-22-14-000-001).
(3) If the fault the continues: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 舱门 DOORS(84)