「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞52-41-00∞∞∞∞∞∞∞∞∞∞Page 208
Nov 01/03 CES
R R R R (4) If the fault continues: - replace the SDAC-2 (1WV2) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
B. Test
(1) On the ECAM control panel: - push the DOOR key to get the DOOR/OXY page.
(2) Make sure that the FWD AVIONIC indication and the door symbol come into view green.
5. Close-up________
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF. (Ref. AMM TASK 31-60-00-860-002)
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
TASK 52-41-00-810-804
Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Aft Avionics-Compartment-Door
1. Possible Causes
_______________
- PROX SW-FRAME, AFT AVIONICS COMPT DOOR (40WV) R - SDAC-1 (1WV1) R - SDAC-2 (1WV2) R - wiring R
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-41-00-861-002
AMM 24-41-00-862-002
R AMM 31-55-34-000-001 R AMM 31-55-34-400-001
AMM 31-60-00-860-001 R AMM 52-71-00-820-008 R R R AMM 52-71-00-820-008 R R
AMM 52-71-14-000-001
AMM 52-71-14-400-001
ASM 31-54/05
3. Fault Confirmation
__________________
A. Job Set-UpEnergize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External Power Removal of the SDAC (1WV1,1WV2) Installation of the SDAC (1WV1,1WV2)EIS Start Procedure Adjustment of the Proximity Switches (23WV, 38WV, 40WV) of the Avionics Compartment Doors with the CHECKING TOOL-DOORS Adjustment of the Proximity Switches (23WV, 38WV, 40WV) of the Avionics Compartment Doors with the lower ECAM DURemoval of the Proximity Switches (23WV, 36WV, 38WV, 40WV) of the Avionics Compartment DoorsInstallation of the Proximity Switches (23WV, 36WV, 38WV, 40WV) of the Avionics Compartment Doors
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞52-41-00∞∞∞∞∞∞∞∞∞∞Page 210
Nov 01/03 CES
B. Test
(1) On the ECAM control panel:
- push the DOOR key to get the DOOR/OXY page.
(2) Make sure that the Aft AVIONIC indication and the door symbol come
into view amber.
4. Fault Isolation_______________
R A. If the test confirms the fault:
R - do a check for 28VDC between pins A and D of door frame proximity
R switch (40WV) (Ref. ASM 31-54/05).
R (1) If there is no 28VDC:
R - repair the wiring as necessary.
R (2) If there is 28VDC:
R - disconnect the connector of the door frame proximity switch (40WV)
R - install the jumper wire between the pins B and C of the door frame
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 舱门 DOORS(115)