- do a check and adjust as necessary the PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2) (Ref. AMM TASK 52-71-00-820-007)
(3) If the fault continues:
 - install the jumper wire between the: PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2) connector A/C and A/B (Ref. ASM 31-54/05).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞52-22-00∞∞∞∞∞∞∞∞∞∞Page 207
 May 01/04 CES
 (a) If the message EMER EXIT goes off:
- replace the PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2) (Ref. AMM TASK 52-71-13-000-003) and (Ref. AMM TASK 52-71-13-400-003).
- remove the jumper wire.
(b) If the message EMER EXIT remains on:
- remove the jumper wire.
- do a check and repair the wiring between: the PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2) connector A/C and ground (Ref. ASM 31-54/05).
(c) If the fault continues:
 - do a check for 28VDC between the: PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2) connector A/A and A/D (Ref. ASM 31-54/05).
 1_ If there is no 28VDC: 
 - do a check for a continuity between: 
 the IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT (21WN2) 
 connectors A/S and A/A (Ref. ASM 31-54/05).
 a If there is continuity:
_
 - do a check and repair the wiring between: IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT (21WN2) connector A/A and CB PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2), EIS/SLIDES/ARM AND WARN/GND (13WN) A/A and IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT (21WN2) A/S, PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2)
 b If there is no continuity:
_
 - replace the IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT (21WN2) (Ref. AMM TASK 52-73-22-000-003) and (Ref. AMM TASK 52-73-22-400-003).
 2 If there is 28VDC:
_ replace the PROX SW-HANDLE FLAP, R FWD EMER EXIT (19WV2) (Ref. AMM TASK 52-71-13-000-003) and (Ref. AMM TASK 52-71-13-400-003).
 5. Close-up
________
 A. Do the test as given in para. 3
TASK 52-22-00-810-803
 Disagree between the DOOR/OXY Page of the ECAM System and the locked LH AFT
 Emergency Exit Door
 1. Possible Causes
_______________
 - PROX SW-HOOK, L AFT EMER EXIT (61WV1)
- SDAC-1 (1WV1)
- SDAC-2 (1WV2)
- EIS/SDAC1 AND 2/DOOR/DET/PAX (48WV)
- IND LT-SLIDE ARMED, L EMER EXIT (2WN1)
- PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1)
- EIS/SLIDES/ARM AND WARN/GND (13WN)
- wiring
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
AMM 24-41-00-861-002  Energize the Aircraft Electrical Circuits from the
 External Power
 AMM 31-60-00-860-001 EIS Start Procedure
 AMM 52-22-00-410-001 Closing of the Emergency Exit Doors from the
 Passenger Compartment
 AMM 52-71-00-820-005  Adjustment of the Proximity Switches (59WV1,59WV2,61WV1,61WV2) of the Emergency Exits with the CHECKING TOOL-DOORS
 AMM 52-71-00-820-007  Adjustment of the Proximity Switches (19WV1, 19WV2, 21WV1,21WV2) of the Emergency Exit Doors with the CHECKING TOOL-DOORS
 AMM 52-71-13-000-003 Removal of the Proximity Switches 59WV1, 59WV2, 61WV1 and 61WV2 AMM 52-71-13-400-003 Installation of the Proximity Switches 59WV1, 59WV2, 61WV1 and 61WV2 AMM 52-73-22-000-003 Removal of the CABIN PRESSURE Warning Light Panel (19WN1,19WN2,20WN1,20WN2) of the Emergency Exit
 AMM 52-73-22-400-003  Installation of the CABIN PRESSURE Warning Light
 Panel of the Emergency Exit Door
 (19WN1,19WN2,20WN1,20WN2)
 ASM 31-54/05
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞52-22-00∞∞∞∞∞∞∞∞∞∞Page 209
 May 01/04 CES
 3. Fault Confirmation
__________________
 A. Aircraft Maintenance Configuration
 (1) Energize the aircraft electrical circuits
 