3. Fault Confirmation
__________________
A. Aircraft Maintenance Configuration
(1) Close the FWD cargo compartment door (referred to as cargo door) in the normal mode (Ref. AMM TASK 52-30-00-860-002).
NOTE : Make sure that a second person does not operate the AFT cargo
____
door.
(2) Close the AFT cargo door in the normal mode (Ref. AMM TASK 52-30-00-860-002).
NOTE : Make sure that a second person does not operate the FWD cargo
____
door.
4. Fault Isolation
_______________
R **ON A/C 001-049, 101-105,
A. If the fault confirmation gives that only the FWD cargo door does not close and the ELEC PUMP-Y (3075GX) does not operate (fault in the door control system):
- do a check for 28 VDC between: the RELAY-TIME (6MJ) connector A/B1 and GND (Ref. ASM 52-35/01).
NOTE : Make sure that the selector of the manual selector valve 2501MJ is
____ set to CLOSE during the fault isolation procedure.
(1) If there is no 28 VDC:
- do a check for 28 VDC between the RELAY-TIME (6MJ) connector A/C1 and GND (Ref. ASM 52-35/01).
(a) If there is 28 VDC:
- do a check for 28 VDC between: the RELAY-TIME (6MJ) connector A/X1 and GND (Ref. ASM 52-35/01).
1 If there is no 28 VDC:
_
- do a check and repair the wiring as necessary betwen: the RELAY-TIME (6MJ) connector A/X1 and the CB (1MJ) (Ref. ASM 52-35/01).
2 If there is 28 VDC:
_
- replace the RELAY-TIME (6MJ).
(b) If there is no 28 VDC:
- do acheck for 28 VDC between: the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D1 and GND (Ref. ASM 52-35/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞52-36-00∞∞∞∞∞∞∞∞∞∞Page 222
May 01/05 CES 1 If there is 28 VDC:
_
- do a check for continuity between: the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D1 and A/D2 (Ref. ASM 52-35/01).
2 If there is continuity:
_
- do a check and repair the wiring as necessary between: the RELAY-TIME (6MJ) connector A/C1 and the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D2 (Ref. ASM 52-35/01).
3 If there is no continuity:
_
- replace the RELAY-L/G POSITION, SYS 2 (12GB)
4 If there is no 28 VDC:
_
- do a check and repair the wiring as necessary between: the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D1 and LGCIU-2 (5GA2) connector AA/8A (Ref. ASM 52-35/01).
(2) If the fault continues:
- do a check for a GND signal at: the LGCIU-2 (5GA2) connector AA/9A (Ref. ASM 52-35/01).
(a) If there is no GND signal:
- do a check and repair each part of the wiring between: the LGCIU-2 (5GA2) connector AA/9A and the connector A/A of 7550VC (Ref. ASM 52-35/01).
1 If the fault continues:
_
- do a check and repair the wiring between: the connector A/A of 7550VC and GND (Ref. ASM 52-35/01).
(3) If the fault continues:
- do a check for 28 VDC between: the LGCIU-2 (5GA2) connector AA/7A and GND (Ref. ASM 52-35/01).
(a) If there are no 28 VDC:
- do a check for continuity between: the MAN SEL VALVE-FWD CARGO DOOR (2501MJ) connectors A/B and the LGCIU-2 (5GA2) connector AA/7A (Ref. ASM 52-35/01).
1 If there is no continuity:
_
- do a check and repair the wiring as necessary between: the MAN SEL VALVE-FWD CARGO DOOR (2501MJ) connector A/B and LGCIU-2 (5GA2) connector AA/7A (Ref. ASM 52-35/01).
2 If there is continuity:
_
- do a check for 28 VDC between: the MAN SEL VALVE-FWD CARGO DOOR (2501MJ) connector A/A and GND (Ref. ASM 52-35/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, ∞∞52-36-00∞∞∞∞∞∞∞∞∞∞Page 223
May 01/05 CES 3 If there are no 28 VDC:
_
- do a check and repair the wiring as necessary between: the MAN SEL VALVE-FWD CARGO DOOR (2501MJ) connector A/A and the CB (1MJ) (Ref. ASM 52-35/01). the MAN SEL VALVE-FWD CARGO DOOR (2501MJ) connector A/C and GND (Ref. ASM 52-35/01).
4 if there is 28 VDC:
_
- replace the MAN SEL VALVE-FWD CARGO DOOR (2501MJ) (Ref. AMM TASK 52-36-15-000-001) and (Ref. AMM TASK 52-36-15-400-001).
(4) If the fault continues:
- make sure that the clearance between the target and the proximity sensor (SW-LOCKING SHAFT (5MJ)) is correctly adjusted (Ref. AMM TASK 52-35-13-400-002).
(a) If the fault continues:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 舱门 DOORS(105)