TASK 52-36-00-810-802
Fault during the Opening Procedure of the AFT Cargo-Compartment Door
1. Possible Causes
_______________
- ELEC PUMP-Y (3075GX)
- RELAY-TIME (6MJ)
- RELAY-L/G POSITION, SYS 2 (12GB)
- LGCIU-2 (5GA2)
- MAN SEL VALVE-AFT CARGO DOOR (2504MJ)
- SW-LOCKING SHAFT (12MJ)
- ACTUATOR-AFT CARGO DOOR, FWD (2505MJ)
- ACTUATOR-AFT CARGO DOOR, AFT (2506MJ)
- SEL VALVE-CARGO DOORS ELEC/MAN CTL (2500MJ)
- wiring
- CB (1MJ)
- CHECK VALVE-DOUBLE (3717GM)
- RELAY (13MJ)
- RELAY (14MJ)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
32-31-00-810-802 LGCIU Fault 32-31-00-810-835 Cargo Door (Aft) Lockshaft Proximity Sensor Fault
(12MJ) ASM 523501S01 AMM 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump AMM 52-30-00-860-003 Open the FWD or AFT Cargo-Compartment Door with the Hand Pump
R AMM 52-35-13-400-002 Installation of the Proximity Switches 5MJ and 12MJ AMM 52-36-12-000-001 Removal of the Electro-Manual Selector Valve 2500MJ AMM 52-36-12-400-001 Installation of the Electro-Manual Selector Valve
2500MJ AMM 52-36-13-000-001 Removal of Double Check Valve 3717GM AMM 52-36-13-400-001 Installation of Double Check Valve 3717GM AMM 52-36-15-000-001 Removal of the Manual Selector Valve 2501MJ/2504MJ AMM 52-36-15-400-001 Installation of the Manual Selector Valve
2501MJ/2504MJ
AMM 52-36-18-000-001 Removal of the Door Actuator
2502MJ/2503MJ/2505MJ/2506MJ
AMM 52-36-18-400-001 Installation of the Door Actuator
2502MJ/2503MJ/2505MJ/2506MJ
ASM 52-35/01
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞52-36-00∞∞∞∞∞∞∞∞∞∞Page 213
May 01/01 CES 3. Fault Confirmation
__________________
A. Aircraft Maintenance Configuration
(1) Open the AFT cargo compartment door (referred to as cargo door) in the normal mode (Ref. AMM TASK 52-30-00-860-001).
NOTE : Make sure that a second person does not operate the FWD cargo
____
door.
(2) Open the FWD cargo door in the normal mode (Ref. AMM TASK 52-30-00-860-001).
NOTE : Make sure that a second person does not operate the AFT cargo
____
door.
4. Fault Isolation
_______________
R **ON A/C 001-049, 101-105,
A. If the fault confirmation gives that only the AFT cargo door does not open and the ELEC PUMP-Y (3075GX) does not operate (fault in the door control system):
- do a check for 28 VDC between: the RELAY-TIME (6MJ) connector A/B1 and GND (Ref. ASM 52-35/01).
NOTE : Make sure that the selector of the manual selector valve 2504MJ is
____ set to OPEN during the fault isolation procedure.
(1) If there is 28 VDC:
- do a check for 28VDC between the RELAY-TIME (6MJ) connector A/C1 and GND (Ref. ASM 52-35/01).
(a) If there is 28 VDC:
- do a check for 28 VDC between: the RELAY-TIME (6MJ) connector A/X1 and GND (Ref. ASM 52-35/01).
1 If there is 28 VDC:
_
- replace the RELAY-TIME (6MJ).
(b) If there is no 28 VDC:
- do a check for for 28 VDC: the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D1 and GND (Ref. ASM 52-35/01).
1 If there is 28 VDC:
_
- do a check for continuity: the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D1 and A/D2 (Ref. ASM 52-35/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞52-36-00∞∞∞∞∞∞∞∞∞∞Page 214
May 01/05 CES 2 If there is continuity:
_
- do a check and repair the wiring as necessary between: the RELAY-TIME (6MJ) connector A/C1 and the RELAY-L/G POSITION, SYS 2 (12GB) connector A/D2 (Ref. ASM 52-35/01).