_
- replace the RELAY-PWR SPLY SWITCHOVER (12WN) (Ref. ASM 52-73/01).
4 If the fault continues:
_
- do a check for a short to ground at the wiring from the circuit breaker (13WN) to the indicator light (3WN2) : pin 2 to pin A (Ref. ASM 52-73/01) and (Ref. ASM 52-73/01).
a If there is no short to ground:
_
- replace the C/B-EIS/SLIDES/ARM AND WARN/GND (13WN) (Ref. ASM 52-73/01).
b If there is a short to ground:
_ - replace the related wiring.
(b) If the circuit breaker stays closed and the fault continues:
- replace the indicator light (3WN2) (Ref. AMM TASK 52-73-21-000-001) and (Ref. AMM TASK 52-73-21-400-001)
- replace the indicator light (2WN2) (Ref. AMM TASK 52-73-21-000-001) and (Ref. AMM TASK 52-73-21-400-001).
- replace the indicator light (1WN2) (Ref. AMM TASK 52-73-21-000-001) (Ref. AMM TASK 52-73-21-400-001).
- replace the RELAY-PWR SPLY SWITCHOVER (12WN) (Ref. ASM 52-73/01).
B. Test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
Open the aft right passenger/crew Make sure that the SLIDE ARMED white door with the handle of the escape indicator light of the aft right slide in the ARMED position. passenger/crew door is on.
5. Close-up
________
A. Aircraft Maintenance Configuration
(1) Install the escape slide or escape slide/raft pack assembly (Ref. AMM TASK 25-62-44-400-001).
(2) Arm the percussion system of the door damper and emergency operation cylinder (Ref. AMM TASK 52-10-00-860-002).
TASK 52-13-00-810-802
The SLIDE ARMED indicator light of the aft left passenger/crew door is
inoperative on ground
1. Possible Causes
_______________
- IND LT-SLIDE ARMED, AFT L DOOR (3WN1)
- IND LT-SLIDE ARMED, L EMER EXIT (2WN1)
- IND LT-SLIDE ARMED, FWD L DOOR (1WN1)
- wiring from the proximity switch (17WV1) to the indicator light (3WN1)
- wiring from the proximity switch (17WV1) pin C to the ground
- wiring from the indicator light (3WN1) and the indicator light (2WN1)
- wiring from the indicator light (2WN1) to the indicator light (1WN1)
- wiring from the indicator light (1WN1) to the relay (12WN)
- RELAY-PWR SPLY SWITCHOVER (12WN)
- wiring from the relay (12WN) to the circuit breaker (13WN)
- C/B-EIS/SLIDES/ARM AND WARN/GND (13WN)
- wiring from the circuit breaker (13WN) to the indicator light (3WN1)
- RELAY-PWR SPLY SWITCHOVER (13WN)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R AMM 25-62-44-000-002 Escape-Slide Pack-Assembly - Removal R AMM 25-62-44-400-001 Escape-Slide Pack-Assembly - Installation AMM 52-10-00-860-001 Special Precautions before Work on the Passenger/Crew Door AMM 52-10-00-860-002 Special Precautions after Work on the Passenger/Crew Door AMM 52-73-21-000-001 Removal of the SLIDE ARMED Indicator-Light (1WN1, 1WN2) of the FWD Passenger/Crew Door AMM 52-73-21-400-001 Installation of the SLIDE ARMED Indicator-Light
中国航空网 www.aero.cn
航空翻译 www.aviation.cn