「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-81∞∞∞∞∞∞∞∞∞∞Page A208
Feb 01/05R CES
2_ If there is continuity:
- do a check and repair the wiring from DMC2 (1WT2) pins
AB/9D, 9E to the first terminal block (Ref. ASM 31-61/04).
(2) If this test gives no maintenance message:
- replace the PFD-F/O (2WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
(a) If the fault continues:
- do a check of the wiring from F/O PFD (2WT2) pins AA/35, 36 to the first terminal block (Ref. ASM 31-61/04).
1 If there is no continuity:
_ - repair the wiring.
2 If there is continuity:
_
- do a check and repair the wiring from F/O PFD (2WT2) pins AA/38, 39 to the first terminal block (Ref. ASM 31-61/04).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-81∞∞∞∞∞∞∞∞∞∞Page A209
Feb 01/05R
CES Failure of the Lower ECAM DU Pin Programming Detected by the DMC2
1. Possible Causes
_______________
- DU-ECAM, LOWER (4WT2)
- ground signals at lower ECAM DU (4WT2) connector AA
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-004 EIS System Test
AMM 31-63-22-000-001 Removal of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
AMM 31-63-22-400-001 Installation of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
AWM 31-68-06
3. Fault Confirmation
__________________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. Test
Do the EIS input test (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 401-499,
A. Test
Do the EIS system test (Ref. AMM TASK 31-60-00-740-004).
**ON A/C ALL
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message:
DMC2: DU ECAM2 POS PIN
- do a check for ground signals at lower ECAM DU (4WT2) connector AA (Ref. AWM 31-68-06).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-81∞∞∞∞∞∞∞∞∞∞Page A210
Aug 01/05 CES
(1) If the wiring is not correct:
- repair the wiring.
(2) If the wiring is correct:
- replace the DU-ECAM, LOWER (4WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
B. Do the test given in Para. 3.
R **ON A/C 401-499,
A. If the test gives the maintenance message WRG: PIN PROG/DU SD(4WT2)
- do a check for ground signals at lower ECAM DU (4WT2) connector AA (Ref. AWM 31-68-06).
(1) If the wiring is not correct:
- repair the wiring.
(2) If the wiring is correct:
- replace the DU-ECAM, LOWER (4WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
B. Do the test given in Para. 3.
R **ON A/C ALL
TASK 31-63-81-810-856
Loss of the High Speed Bus Input Detected by the DMC1
1. Possible Causes
_______________
- DMC-1 (1WT1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-68/05
3. Fault Confirmation
__________________
A. Test
Do the EIS input test (Ref. AMM TASK 31-60-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
DMC1: NO DMC HS3 DATA