• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:37来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 201-299, 301-399, Aug 01/05 CES

 

 (b) If there is a ground signal:
 - do a check for a ground signal at pin AB/4H of the DMC3 (1WT3) (Ref. ASM 31-68/02).
 1 If there is no ground signal:
_

 - do a check of the wiring from DMC3 (1WT3) pin AB/4H to the first terminal block (Ref. ASM 31-68/02).
 a If there is no continuity:
_

 - repair the wiring.
 b If there is continuity:

_

 - replace the DMC-3 (1WT3) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
 C. Do the EIS start procedure (F/O PFD only) (Ref. AMM TASK 31-60-00-860-001) and make sure that the F/O PFD comes on.
 5. Close-up
________
 A. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 224
 201-299, 301-399, Aug 01/05 CES

 

 Loss of the F/O ND
 1. Possible Causes
_______________
 - ND-F/O (3WT2)

 - DMC-3 (1WT3)

 - DMC-2 (1WT2)

 - wiring

 - C/B-EIS/ND/F/O (12WT2)

 - POT-ND, F/O (8WT2)

 - C/B-EIS/ND/F/O/SWTG (23WT2)

 - RELAY-BUS1 TO ESS BUS SWTG, DMC3 (26WT)

 - C/B-EIS/DMC3/SWTG (21WT3)

 - SEL SW-EIS DMC (18WT)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
IPC 316808 AMM 31-60-00-860-001 EIS Start Procedure AMM 31-60-00-860-002 EIS Stop Procedure AMM 31-63-22-000-001 Removal of the Display Unit
 (2WT1,2WT2,3WT1,3WT2,4WT1,4WT2) AMM 31-63-22-400-001 Installation of the Display Unit
 (2WT1,2WT2,3WT1,3WT2,4WT1,4WT2) AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3) AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3) ASM 31-61/02 ASM 31-68/01 ASM 31-68/02
 3. Fault Confirmation
__________________
 A. Job Set-Up Do the EIS start procedure (F/O ND only) (Ref. AMM TASK 31-60-00-860-001).
 B. Test
 Make sure that the F/O ND stays off.

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 225
 201-299, 301-399, Aug 01/05 CES

 

 4. Fault Isolation
_______________
 A. If the F/O ND stays off and if the EIS DMC selector switch (18WT) on the SWITCHING panel 8VU is at NORM:
 (1) Do a check for 115VAC at pin AA/104 of the F/O ND (3WT2) (Ref. ASM 31-61/02).
 (a) If there is 115VAC:

 - replace the ND-F/O (3WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).

 (b) If there is no 115VAC:


 - do a check for a ground signal at pin AA/102 of the F/O ND (3WT2).
 1_ If there is no ground signal:
 - repair the wiring from F/O ND (3WT2) pin AA/102 to the
 ground terminal.

 2 If there is a ground signal:
_

 - do a check of the wiring from F/O ND (3WT2) pin AA/104 to the circuit breaker (12WT2).
 a If there is no continuity:
_ - repair the wiring.

 b If there is continuity:
_ - replace the C/B-EIS/ND/F/O (12WT2).

 (2) If the fault continues:
 - do a check of the wiring from F/O ND (3WT2) pins AA/49, 50, 51, 52 to F/O ND potentiometer (8WT2) pins A/2, 4, 5, 6 (Ref. ASM 31-68/01).
 (a) If there is continuity:
 - replace the ND-F/O (3WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
 1 If the fault continues:
_

 - replace the POT-ND, F/O (8WT2) (Ref. IPC 316808).
 (b) If there is no continuity:
 - repair the wiring from F/O ND (3WT2) pins AA/49, 50, 51, 52 to F/O ND potentiometer (8WT2) pins A/2, 4, 5, 6.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 226
 201-299, 301-399, Aug 01/05 CES

 

 B. If the F/O ND stays off and if the EIS DMC selector switch (18WT) on the SWITCHING panel 8VU is at F/O/3:
 (1) Do a check for 28VDC at pin AA/93 on the F/O ND (3WT2) (Ref. ASM 31-61/02).
 