• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:37来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -------------------------------------------------------------------------------
AMM 31-60-00-860-001 EIS Start Procedure
 AMM 31-60-00-860-002 EIS Stop Procedure
 AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
 AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
 ASM 31-62/01

 3. Fault Confirmation
__________________
 A. Job Set-up
 (1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
 4. Fault Isolation
_______________
 A. Make sure that:
 - the INVALID DATA message is shown on the CAPT PFD DU and on the CAPT ND DU

 - the ECAM warning EIS DMC 1 FAULT is shown on the upper ECAM display


 (1) Replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).

 (2) If the fault continues:


 - Make sure that there is 115VAC on the pin AC-2 of the DMC1(1WT1)
 (a) If there is no 115VAC:
 - check and repair the wiring from the DMC1(1WT1) pin AC-2 to the EIS DMC1 SPLY (10WT1)- circuit breaker
 1 if there is continuity:
_ - replace the EIS/DMC1/SPLY (10WT1) (Ref. ASM 31-62/01)

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 274
 Aug 01/05 CES (b) If there is 115VAC:

 

 - Make sure that there is a ground signal at pin AC-7 of the DMC1(1WT1)
 1 if there is no ground signal:
_

 - repair the wiring from the DMC1 (1WT1) pin AC-7 to the ground terminal (Ref. ASM 31-62/01).
 B. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).

 

 Loss of the ARINC 629 link from the FO DU's to the DMC2
 1. Possible Causes
_______________
 - DMC-2 (1WT2)

 - EIS/DMC2/SPLY (10WT2)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 31-60-00-860-001 EIS Start Procedure
 AMM 31-60-00-860-002 EIS Stop Procedure
 AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
 AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
 ASM 31-62/01

 3. Fault Confirmation
__________________
 A. Job Set-up
 (1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
 4. Fault Isolation
_______________
 A. Make sure that:
 - the INVALID DATA message is shown on the F/O PFD DU and on the F/O ND DU

 - the ECAM warning EIS DMC 2 FAULT is shown on the upper ECAM display


 (1) Replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).

 (2) If the fault continues:


 - Make sure that there is 115VAC on the pin AC-2 of the DMC2(1WT2)
 (a) If there is no 115VAC:
 - check and repair the wiring from the DMC2(1WT2) pin AC-2 to the EIS DMC1 SPLY (10WT2)- circuit breaker
 1 if there is continuity:
_ - replace the EIS/DMC2/SPLY (10WT2) (Ref. ASM 31-62/01)

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 276
 Aug 01/05 CES (b) If there is 115VAC:

 

 - Make sure that there is a ground signal at pin AC-7 of the DMC2(1WT2)
 1 if there is no ground signal:
_

 - repair the wiring from the DMC2 (1WT2) pin AC-7 to the ground terminal (Ref. ASM 31-62/01).
 B. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).

 


 Loss of the ARINC 629 link from the FO DU's to the DMC3
 1. Possible Causes
_______________
 - DMC-3 (1WT3)

 - EIS/DMC3/STBY/SPLY (14WT1)

 - EIS/DMC3/SPLY (10WT3)

 - RELAY-BUS1 TO ESS BUS SWTG, DMC3 (26WT)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-860-001 EIS Start Procedure
 AMM 31-60-00-860-002 EIS Stop Procedure
 AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 3(123)