- repair the wiring from EIS DMC selector switch (18WT) pin 13 to the ground terminal.
 b If there is a ground signal:
_
 - do a check and repair the wiring from ECAM/ND XFR selector switch (19WT): . pin 14 to EIS DMC selector switch (18WT) pin 14 . pin 13 to DMC3 (1WT3) pin AB/8J.
 2 If there is a ground signal:
_
 - replace the DMC-3 (1WT3) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001). 
R **ON A/C 401-499,
 A. If the EIS-DMC selector switch (18WT) is at NORM and you cannot get the ECAM DU image on the F/O ND DU:
 - do a check for a ground signal at the pin AE-4D of the DMC2 (1WT2)
 (1) If there is a ground signal:
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(2) If there is no ground signal :
 - do a check and repair the wiring from the pin AE-4D of the DMC2 (1WT2) to the first terminal block (Ref. ASM 31-68/01)
 B. If the EIS-DMC selector switch (18WT) is at F/O/3 and you cannot get the ECAM DU image on the F/O ND DU:
 - do a check for a ground signal at the pin AE-4D of the DMC3 (1WT3)
 (1) If there is a ground signal:
- replace the DMC-3 (1WT3) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(2) If there is no ground signal :
 - do a check and repair the wiring from the pin AE-4D of the DMC3 (1WT3) to the first terminal block (Ref. ASM 31-68/03)
R  C. If you cannot get the image at the F/O ND DU when the EIS DMC selector  
R  switch is at NORM or at F/O/3 position:  
R  - do a check for a ground signal at the pin 5 of the ECAM PFD/ND XFR  
R  pushbutton switch (19WT)  
R  (1) If there is no ground signal :  
R  - do a check and repair the wiring from the pin 5 of the ECAM PFD/ND  
R  XFR (19WT) to the first terminal block (Ref. ASM 31-68/03)  
R  (2) If there is a ground signal:  
R  - do a check and repair the wiring from the pin 8 of the ECAM PFD/ND  
R  XFR (19WT) to the first terminal block (Ref. ASM 31-68/01)  
R  (a) If the wiring is correct:  
R  - replace the SEL SW-ECAM/ND XFR (19WT).  
R  **ON A/C ALL  
R  D. Set the ECAM/ND XFR selector switch (19WT) to F/O and make sure that the 
 transfer is possible. 
 5. Close-up________ 
 A. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
R **ON A/C 401-499,
 TASK 31-63-82-810-821
 Feedback Message from the DMC2 on the Lower ECAM DU
 1. Possible Causes
_______________
 - DMC-2 (1WT2)
- ND-F/O (3WT2)
- DU-ECAM, LOWER (4WT2)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-004 EIS System Test
 AMM 31-63-22-000-001 Removal of the Display Unit
 (2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
 AMM 31-63-22-400-001 Installation of the Display Unit
 (2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
 AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
 AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
 3. Fault Confirmation
__________________
 A. Test
 - Not applicable, the fault cannot be confirmed.
 4. Fault Isolation
_______________
 A. Read the Post Flight Report
 (1) If the PFR gives the maintenance message:
 DMC2(1WT2)/DU ND FO(3WT2)/DU SD(4WT2)
 - replace the DMC-2 (1WT2) and the ND-F/O (3WT2) (Ref. AMM TASK 31-63-34-000-001) (Ref. AMM TASK 31-63-34-400-001) (Ref. AMM TASK 31-63-22-000-001) (Ref. AMM TASK 31-63-22-400-001)
 B. Do the EIS system test (Ref. AMM TASK 31-60-00-740-004)
 (1) If the test gives the maintenance message DU SD(4WT2)/DMC2(1WT2)
 - replace the DU-ECAM, LOWER (4WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 249
 Aug 01/05 CES Feedback Message from the DMC3 on the CAPT PFD DU
 1. Possible Causes
_______________
 - DMC-3 (1WT3)
- ND-F/O (3WT2)
- PFD-CAPT (2WT1)
中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 3(115)