- repair the wiring. b If there is continuity:
_ - replace the C/B-EIS/DMC3/SWTG (21WT3).
(4) If the fault continues:
- do a check for a ground signal at pin AB/8H, 4C of the DMC1 (1WT1).
(a) If there is no ground signal:
- do a check for a ground signal at pin AA/2 of the EIS DMC selector switch (18WT) (Ref. ASM 31-68/02).
1 If there is no ground signal:
_
- replace the SEL SW-EIS DMC (18WT). 2 If there is a ground signal:
_
- do a check of the wiring from EIS DMC selector switch (18WT) pin 2 to DMC1 (1WT1) pin AB/8H, 4C.
a If there is no continuity:
_
- repair the wiring. b If there is continuity:
_
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 218
201-299, 301-399, Aug 01/05 CES
(b) If there is a ground signal:
- do a check for a ground signal at pin AB/4C of the DMC3 (1WT3) (Ref. ASM 31-68/02).
1 If there is no ground signal:
_
- do a check of the wiring from DMC3 (1WT3) pin AB/4C to the first terminal block (Ref. ASM 31-68/02).
a If there is no continuity:
_
- repair the wiring.
b If there is continuity:
_
- replace the DMC-3 (1WT3) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
C. Do the EIS start procedure (upper ECAM DU only) (Ref. AMM TASK 31-60-00-860-001) and make sure that the upper ECAM DU comes on.
5. Close-up
________
A. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 219
201-299, 301-399, Aug 01/05 CES
Loss of the F/O PFD
1. Possible Causes
_______________
- PFD-F/O (2WT2)
- DMC-3 (1WT3)
- DMC-2 (1WT2)
- wiring
- C/B-EIS/PFD/F/O (11WT2)
- POT-PFD, F/O (7WT2)
- C/B-EIS/PFD/F/O/SWTG (22WT2)
- RELAY-BUS1 TO ESS BUS SWTG, DMC3 (26WT)
- C/B-EIS/DMC3/SPLY (10WT3)
- C/B-EIS/DMC3/SWTG (21WT3)
- SEL SW-EIS DMC (18WT)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
IPC 316808 AMM 31-60-00-860-001 EIS Start Procedure AMM 31-60-00-860-002 EIS Stop Procedure AMM 31-63-22-000-001 Removal of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2) AMM 31-63-22-400-001 Installation of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2) AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3) AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3) ASM 31-61/02 ASM 31-68/01 ASM 31-68/02
3. Fault Confirmation
__________________
A. Job Set-Up Do the EIS start procedure (F/O PFD only) (Ref. AMM TASK 31-60-00-860-001).
B. Test
Make sure that the F/O PFD stays off.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞31-63-82∞∞∞∞∞∞∞∞∞∞Page 220
201-299, 301-399, Aug 01/05 CES
4. Fault Isolation
_______________
A. If the F/O PFD stays off and if the EIS DMC selector switch (18WT) on the SWITCHING panel 8VU is at NORM:
(1) Do a check for 115VAC at pin AA/104 of the F/O PFD (2WT2) (Ref. ASM 31-61/02).
(a) If there is 115VAC:
- replace the PFD-F/O (2WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
(b) If there is no 115VAC:
- do a check for a ground signal at pin AA/102 of the F/O PFD (2WT2).
1_ If there is no ground signal:
- repair the wiring from F/O PFD (2WT2) pin AA/102 to the
ground terminal.
2 If there is a ground signal:
_
- do a check of the wiring from F/O PFD (2WT2) pin AA/104 to the circuit breaker (11WT2).
a If there is no continuity:
_ - repair the wiring.
b If there is continuity: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 3(105)