 ELEC PUMP (3808GX) connectors A/G and A/D (Ref. ASM 29-
24/01).

_

 - replace the CT-Y ELEC PUMP (3807GX) (Ref. AMM TASK 29-24-15-000-001) and (Ref. AMM TASK 29-24-15-400-001).
 b If the fault continues:
_

 - replace the DET-PHASE UNBALANCE, Y ELEC PUMP (3808GX) (Ref. AMM TASK 29-24-16-000-001) and (Ref. AMM TASK 29-24-16-400-001).
 c If the fault continues:
_

 - do a check of the wiring between: the ELEC PUMP-Y (3075GX) connector A/A, A/B, A/C and the CB (3801GX) (Ref. ASM 29-24/01).
 d If the fault continues:
_

 - do a check of the wiring between: the ELEC PUMP-Y (3075GX) connector A/A, A/B, A/C and the CB (3802GX) (Ref. ASM 29-24/01).
 e If there are no 28 VDC:
_

 - do a check of the wiring between: the DET-PHASE UNBALANCE, Y ELEC PUMP (3808GX) connector A/F and the CB (3803GX) and repair as necessary (Ref. ASM 29-24/01).
 B. Do the test as given in Para. 3. A. to make sure that the operation is correct.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-24-00∞∞∞∞∞∞∞∞∞∞Page 204
 Nov 01/04R
 CES


 TASK 29-24-00-810-802

 

 Overheat Indication of the Yellow Electric Pump
 1. Possible Causes
_______________

 - ELEC PUMP-Y (3075GX)

 - wiring

 

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 29-24-00-710-001 Operational Test of the Yellow Auxiliary Power
 AMM 29-24-51-000-001 Removal of the Electric Pump (3075GX)
 AMM 29-24-51-400-001 Installation of the Electric Pump (3075GX)
 ASM 29-24/01

 3. Fault Confirmation
__________________

 A. Do the operational test of the electric pump of the Yellow hydraulic system (Ref. AMM TASK 29-24-00-710-001).
 4. Fault Isolation
_______________

 A. If the test gives the message HYD Y ELEC PUMP OVHT:
 - disconnect the electrical connector (3075GX-A) and look at the upper ECAM DU.
 (1) If the fault continues:

 - do a check of the wiring between: the ELEC PUMP-Y (3075GX) connector A/F and the SDAC and repair as necessary (Ref. ASM 29-24/01).

 (2) If the fault does not continue:


 - replace the ELEC PUMP-Y (3075GX) (Ref. AMM TASK 29-24-51-000-001) and (Ref. AMM TASK 29-24-51-400-001).
 B. Do the test as given in Para. 3. A. to make sure that the operation is correct.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-24-00∞∞∞∞∞∞∞∞∞∞Page 205
 Nov 01/02R
 CES


 TASK 29-24-00-810-803

 

 Continuous Operation of the Yellow Electric Pump
 1. Possible Causes
_______________
 - RELAY-TIME (6MJ)

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 29-24-00-710-001 Operational Test of the Yellow Auxiliary Power
 3. Fault Confirmation
__________________

 A. Do the operational test of the Yellow electric pump (Ref. AMM TASK 29-24-00-710-001).
 4. Fault Isolation
_______________

 A. If the test gives: the HYD Y SYS LO PR on the upper ECAM DU, normal pressure for the Yellow system (approximately 3000 psi) on the HYD page of the lower ECAM DU, and the Yellow electric pump operates continuously:
 - replace the RELAY-TIME (6MJ).
 NOTE : If the CFDS fault message ATA 29-32-12 AFS: HYD Y 3151GN comes

____ into view, ignore it, because it has no relation to this failure.
 B. Do the test as given in Para. 3. A. to make sure that the operation is correct.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-24-00∞∞∞∞∞∞∞∞∞∞Page 206
 Nov 01/02R
 CES


 TASK 29-24-00-810-804

 

 Yellow Electric Pump Motor Running with no Hydraulic Pressure
 1. Possible Causes
_______________

 - ELEC PUMP-Y (3075GX)
 