A. Make sure that this(these) circuit breaker(s) is(are) closed:
------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION ------------------------------------------------------------------------------121VU HYDRAULIC/RAT/CTL 2801GE P32 49VU HYD/RAT/CTL 2801GE D14 121VU HYDRAULIC/RAT/EXTN/SOL1 2803GE P33 106VU CSM/G /EV/MAN/SPLY 6XE AS01
B. Aircraft Maintenance Configuration
(1) Open the access panel 197EB.
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) On the RAT ground control-panel (3GE):
- Set the 28VDC switch to the ON position.
- Set the LAMP TEST switch to the test position and make sure that all lights come on.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 062-099, 106-149, 151-199, 204-299, ∞∞29-22-00∞∞∞∞∞∞∞∞∞∞Page 209
301-399, 401-499, Aug 01/05 CES
(4) Retract the RAT (Ref. AMM TASK 29-22-00-869-006).
(5) During the retraction of the RAT:
- Obey the interlock warning light in the RAT control panel (3GE).
- Obey the operation of the RAT.
4. Fault Isolation
_______________
A. If the RAT starts to retract but returns to its fully extended position and the interlock warning light on the RAT control panel (3GE) comes on:
- Do the adjustment of the RAT interlock proximity switch (Ref. AMM TASK 29-22-00-820-005).
(1) If the fault continues:
- Replace the RAT interlock proximity switch (Ref. AMM TASK 29-22-51-000-011) and (Ref. AMM TASK 29-22-51-400-011).
R **ON A/C 151-199, 301-399, 401-499,
B. Do the fault confirmation procedure as given in Para. 3. to make sure that the operation is correct.
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
5. Close-up
________
A. Put the aircraft back to the serviceable condition.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(2) Close the access panel 197EB.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 062-099, 106-149, 151-199, 204-299, ∞∞29-22-00∞∞∞∞∞∞∞∞∞∞Page 210
301-399, 401-499, Aug 01/05 CES
R **ON A/C 001-049, 051-061, 101-105, 201-203,
TASK 29-22-00-810-804
Unwanted Deployment of the Ram Air Turbine
1. Possible Causes
_______________
- RELAY-EMER AUTO LOG CONDITION (17XE)
- RELAY-EMER AUTO LOG CONDITION (18XE)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 29-22-00-710-001 Operational Check of Ram Air Turbine (RAT) Automatic Deployment
3. Fault Confirmation
__________________
A. Do the operational test of the ram air turbine (RAT) automatic deployment (Ref. AMM TASK 29-22-00-710-001).
4. Fault Isolation
_______________
A. If the RAT extends as soon as the circuit breaker 9XE or 11XE is opened during the operational test:
- Replace the RELAY-EMER AUTO LOG CONDITION (17XE) if the RAT extends when you open the circuit breaker 9XE.
- Replace the RELAY-EMER AUTO LOG CONDITION (18XE) if the RAT extends when you open the circuit breaker 11XE.
B. Do the test as given in Para. 3. A. to make sure that the operation is correct.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-061, 101-105, 201-203, ∞∞29-22-00∞∞∞∞∞∞∞∞∞∞Page 211
May 01/05 CES
POWER TRANSFER - FAULT ISOLATION PROCEDURES
___________________________________________
TASK 29-23-00-810-801
Fault of the Power Transfer Unit (PTU)
1. Possible Causes
_______________