- MANIFOLD,PTU (3015GM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-23-00-810-802 Continuous Running of the Power Transfer Unit (PTU) AMM 29-13-15-000-001 Removal of the Power Transfer Unit (PTU) Manifold of the Yellow Hydraulic System AMM 29-13-15-400-001 Installation of the Power Transfer Unit (PTU) Manifold of the Yellow Hydraulic System AMM 29-23-51-000-002 Removal of the Solenoid Valve 3012GL of the Power Transfer Unit AMM 29-23-51-400-002 Installation of the Solenoid Valve 3012GL of the
Power Transfer Unit
AMM 71-00-00-710-003 Engine Automatic Start
AMM 71-00-00-710-028 Engine Shutdown
3. Fault Confirmation
__________________
A. Do this test.
(1) Make sure that the PTU P/BSW is in the AUTO position.
(2) Start the engine No. 1 (Ref. AMM TASK 71-00-00-710-003).
(3) Start the engine No. 2 (Ref. AMM TASK 71-00-00-710-003).
(4) Do a check of the PTU for continuous running.
(a) If there is continuous running, do the subsequent steps: 1 On the overhead panel 40VU, set the GREEN/ENG 1 PUMP P/BSW to
_ the OFF position, and after some seconds, back to the ON position.
2 Do again a check for continuous running of the PTU.
_
(5) Shut down the engines (Ref. AMM TASK 71-00-00-710-028).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-23-00∞∞∞∞∞∞∞∞∞∞Page 216
May 01/04R CES
4. Fault Isolation
_______________
**ON A/C 001-049, 051-058, 101-101,
A. If after start of the engine No. 2:
- the PTU starts continuous running and stops after you have switched off and on the GREEN/ENG 1 PUMP P/BSW:
- replace the SOL VALVE-PTU, Y (3012GL) (Ref. AMM TASK 29-23-51-000-002) and (Ref. AMM TASK 29-23-51-400-002)
(1) If the fault continues:
- do the troubleshooting of the continuous running of the PTU (Ref. TASK 29-23-00-810-802).
R **ON A/C 059-099, 102-149, 151-199, 201-299, 301-399, 401-499,
A. If after start of the engine No. 2:
- the PTU starts continuous running and stops after you have switched off and on the GREEN/ENG 1 PUMP P/BSW:
- replace the MANIFOLD,PTU (3015GM) (Ref. AMM TASK 29-13-15-000-001) and (Ref. AMM TASK 29-13-15-400-001).
(1) If the fault continues:
- do the troubleshooting of the continuous running of the PTU (Ref. TASK 29-23-00-810-802).
**ON A/C ALL
B. Do the fault confirmation procedure as given in Para. 3. to make sure that operation is correct.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-23-00∞∞∞∞∞∞∞∞∞∞Page 217
Aug 01/05 CES
TASK 29-23-00-810-806
Continuous Running of the Power Transfer Unit (PTU) After Start in Sequence of
Engine 2 and Engine 1
1. Possible Causes
_______________
- MANIFOLD,PTU (1113GM)
- SOL VALVE-PTU, G (1012GL)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
29-23-00-810-802 Continuous Running of the Power Transfer Unit (PTU) AMM 29-11-15-000-001 Removal of the Power Transfer Unit (PTU) Manifold of the Green Hydraulic System AMM 29-11-15-400-001 Installation of the Power Transfer Unit (PTU) Manifold of the Green Hydraulic System AMM 29-23-51-000-001 Removal of the Solenoid Valve 1012GL of the Power Transfer Unit AMM 29-23-51-400-001 Installation of the Solenoid Valve 1012GL of the
Power Transfer Unit
AMM 71-00-00-710-003 Engine Automatic Start
AMM 71-00-00-710-028 Engine Shutdown
3. Fault Confirmation
__________________
A. Do this test.
(1) Make sure that the PTU P/BSW is in the AUTO position.
(2) Start the engine No. 2 (Ref. AMM TASK 71-00-00-710-003).
(3) Start the engine No. 1 (Ref. AMM TASK 71-00-00-710-003).
(4) Do a check of the PTU for continuous running.
(a) If there is continuous running, do the subsequent steps: 1 On the overhead panel 40VU, set the YELLOW/ENG 2 PUMP P/BSW to
中国航空网 www.aero.cn
航空翻译 www.aviation.cn