WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION
_______
BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE
_______ CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Pressurize the Blue hydraulic system with the electric pump (Ref. AMM TASK 29-10-00-863-003).
(3) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
(4) Operate the sidestick for ailerons, spoilers and elevators at full travel for 5 min.
(5) Operate the rudder pedals at full travel for 5 min.
(6) Operate the flap and slat control lever at full travel for 5 min.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 212
May 01/05R CES
4. Fault Isolation
_______________
A. If the test gives:
- the message HYD B RSVR OVHT on the upper ECAM DU,
- the BLUE ELEC PUMP P/BSW FAULT light on panel 40VU,
- the OVHT flag on the HYD page of the lower ECAM DU:
(1) You must measure the temperature with a temperature sensor adjacent to the XMTR-TEMP, B RSVR (2381GR).
(2) If the temperature is more than 95 +2.2 -2.2 deg.C (203.00 +3.96 -
3.96 deg.F):
- do a check of the internal leakage of the Blue hydraulic system (Ref. AMM TASK 29-00-00-280-002).
(a) If the internal leakage is more than permitted:
1 examine the system to find the defective component.
_
2 replace or repair the defective component.
_
(b) If the internal leakage is not more than permitted:
- do a check of the filter elements of the FILTER-ELEC PUMP CASE DRAIN, B (2084GM), FILTER-HP, B (2048GM) and FILTER-RSVR RETURN, B (2002GM) for contamination and/or parts of a defective check valve
1 If the filter elements are dirty, or you find parts of a
_ defective check valve (spring and/or ball):
a Replace the filter element (Ref. AMM TASK 29-12-43-610-001)
_ or (Ref. AMM TASK 29-12-44-610-001) or (Ref. AMM TASK 29-12-45-610-001).
2 Remove the check valve CHECK VALVE B (2050GM) (Ref. AMM TASK
_
29-12-36-000-001)
a Do a check of the check valve 2050GM for the correct
_
condition.
b If necessary install a new check valve 2050GM (Ref. AMM
_ TASK 29-12-36-400-001).
3 Flush the blue hydraulic system (Ref. AMM TASK 12-36-29-170-
_
003).
(3) If the temperature is less than 95 +2.2 -2.2 deg.C (203.00 +3.96 -
3.96 deg.F):
- do a check for continuity between: XMTR-TEMP, B RSVR (2381GR) connector A/A and connector A/B (Ref. ASM 29-33/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 213
May 01/05R CES
(a) If there is continuity:
- replace the XMTR-TEMP, B RSVR (2381GR) (Ref. AMM TASK 29-33-11-000-002) (Ref. AMM TASK 29-33-11-400-002).
(b) If there is no continuity:
- make sure that the wiring is not connected to GND between: XMTR-TEMP, B RSVR (2381GR) connector A/B and DIODE ((1156VD) connector 31 (Ref. ASM 29-12/01).
1 If the wiring is connected to GND:
_ - repair the wiring as necessary.
(c) If the fault continues:
- do the operational test of the central warning system (Ref. AMM TASK 31-50-00-710-001).
1 If the test gives the maintenance message SDAC1 : B HYD TEMP
_
XMTR 2381GR:
- replace the SDAC-1 (1WV1), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
2 If the test gives the maintenance message SDAC2 : B HYD TEMP
_
XMTR 2381GR:
- replace the SDAC-2 (1WV2), (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
B. Do the test as given in Para. 3. B. to make sure that operation is
correct (no maintenance message shown).
5. Close-up
________
A. Aircraft Maintenance Configuration
(1) Make sure the Blue hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-003).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 液压(40)