The system reservoir 2000GQ is installed in the left-hand belly fairing
aft of the main landing-gear compartment together with the LP filter
2002GM.
The reservoir is filled through the reservoir filling system which is
operated from the ground service panel of the Green hydraulic system. A
reservoir drain valve is installed on the ground service panel of the
Blue hydraulic system.
The reservoir is pressurized with air to 3.5 bar (50 psi). A
depressurization valve 2087GM is installed on the ground service panel of
the Blue hydraulic system.
A pressure switch (2384GH) sends a discrete signal if the pressure in the
reservoir is too low. The signal goes to the two system data aquisition
concentrators (SDAC) for electronic centralized aircraft monitor (ECAM)
warnings. The signal also goes to the overhead panel for FAULT light
operation.
The pressure switch (2387GH) sends a discrete signal through some relays
to the SDAC. If the air pressure in the reservoir decreases to less than
3.1 bar absolute (45 psia) (2.1 bar relative (30 psig)), the pressure switch gives a signal in flight (flight phases 5, 6 and 7) which is then memorized only and displayed after landing (flight phases 8, 9, and 10).
C. Suction System The E-pump gets its supply of fluid directly from the system reservoir 2000GQ.
**ON A/C 301-399,
The Blue main hydraulic system has the subsequent sub-systems:
- a HP system which supplies the consumers,
- a LP or return system through which fluid returns to the reservoir,
- a suction system.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 305
Aug 01/05 CES
A. HP System The electric pump 2075GJ usually pressurizes the HP system. The electric pump starts automatically when any one of the engines starts. It then operates continuously until the two engines are stopped. The pushbutton P/B switch 2704GJ in the flight compartment makes it possible for the crew to stop the electric pump. It is also possible to pressurize the system with the electric pump when the engines are stopped. The P/B switch 2703GJ on the maintenance panel 50VU in the flight compartment stops the automatic function and starts the electric pump.
The Ram Air Turbine (RAT) can also supply the Blue hydraulic system with HP fluid. The RAT extends automatically in flight when there is a total AC failure. It is also possible to extend the RAT from the flight compartment with the P/B switches 2805GE or 24XE.
On the ground, it is possible to pressurize the system from a ground supply. through the self sealing connectors on the ground service panel.
The supply to all of the consumers goes through the HP manifold 2011GM. The HP manifold has pressure switches, a filter, check valves, a transmitter, a solenoid valve and other components which control the system. The supply to all of the consumers other than the slat motor and CSM/G also goes through the leakage-measurement system manifold 2146GM.
B. LP System The LP System returns the fluid from the consumers to the system reservoir 2000GQ. The case drain of the electric pump and the return from the HP manifold are also connected to the LP system. Part of the LP system is also used in the reservoir filling system.
The LP fluid goes through the LP filter 2002GM immediately before it gets
to the system reservoir 2000GQ.
A filter 2084GM is also installed in the case drain line of the electric
pump which goes to the LP system.
The system reservoir 2000GQ is installed in the left-hand belly fairing
aft of the main landing-gear compartment together with the LP filter
2002GM.
The reservoir is filled through the reservoir filling system which is
operated from the ground service panel of the Green hydraulic system. A
reservoir drain valve is installed on the ground service panel of the
Blue hydraulic system.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 306
Aug 01/05R
CES The reservoir is pressurized with air to 3.5 bar (50 psi). A depressurization valve 2087GM is installed on the ground service panel of the Blue hydraulic system.
C. Suction System The E-pump gets its supply of fluid directly from the system reservoir 2000GQ.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 307