3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU HYD/HYD PWR/B WARN/& CTL 2702GJ C12 49VU SDAC/1 AND 2/28VDC/ESS BUS 12WV F05 49VU SDAC/1/SPLY 3WV F04 49VU SDAC/2/26VAC SYNC/AC ESS BUS 6WV F03 49VU SDAC/1/26VAC SYNC/AC ESS BUS 5WV F02 121VU HYDRAULIC/LOW/LVL/IND 1832GQ N32 121VU HYDRAULIC/HYD/QTY/IND 1831GQ P35 121VU EIS/SDAC/2/SPLY 2WV Q06 121VU EIS/SDAC/2/BUS1/26VAC SYNC AC 10WV Q05 121VU EIS/SDAC/1/BUS1/26VAC SYNC AC 9WV Q04 121VU EIS/SDAC/1/BUS2/26VAC SYNC AC 7WV Q03 121VU EIS/SDAC/2/BUS2/26VAC SYNC AC 8WV Q02
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 243
Feb 01/03R CES
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
(3) Look for fault indications on the upper ECAM DU.
4. Fault Isolation
_______________
A. If the Fault Confirmation gives:
-the messages HYD B RSVR LO LVL and HYD B RSVR on the upper ECAM DU:
- Open these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 9WV.
(1) If the fault messages go off:
- replace the SDAC-1 (1WV1) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(2) If the fault continues:
(a) Close these circuit breakers:
- 3WV,
- 5WV,
- 7WV and
- 9WV.
(b) Open these circuit breakers:
- 2WV,
- 6WV,
- 8WV and
- 10WV.
(3) If the fault messages go off:
- replace the SDAC-2 (1WV2) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(4) If the fault continues:
- Do the troubleshooting as given in the subsequent references:
- (Ref. TASK 29-12-00-810-803) and
- (Ref. TASK 29-12-00-810-802).
B. Do the fault confirmation procedure as given in Para. 3. to make sure that the operation is correct.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-12-00∞∞∞∞∞∞∞∞∞∞Page 244
Feb 01/03R CES
TASK 29-12-00-810-815
FAULT Light of the BLUE ELEC PUMP P/BSW is ON at the same Time as the FAULT Light of the ENG1 PUMP P/BSW
1. Possible Causes
_______________
- EIU-1 (1KS1)
- RELAY-OIL LOW PRESS AND GROUND, ENG 1 (10KS1)
- RELAY-OIL LOW PRESS AND GROUND, ENG 1 (11KS1)
- SW-LOW OIL PRESS (4000EN)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power AMM 73-25-34-000-040 Removal of the Engine Interface Unit (EIU) AMM 73-25-34-400-040 Installation of the Engine Interface Unit (EIU) AMM 73-25-34-710-043 Operational Test of the Engine Interface Unit AMM 79-34-15-000-041 Removal of the Low Oil Pressure Switch (4000EN) AMM 79-34-15-400-041 Installation of the Low Oil Pressure Switch (4000EN) ASM 73-25/08 ASM 73-25/09
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU HYD/HYD PWR/B WARN/& CTL 2702GJ C12 121VU HYDRAULIC/G HYD/PUMP ENG1/MONG 1702GK R34
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 液压(52)