「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-10-00∞∞∞∞∞∞∞∞∞∞Page 208
 May 01/05 CES

 

R 3. Fault Confirmation
__________________ R A. Make sure that this(these) circuit breaker(s) is(are) closed: R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION R -------------------------------------------------------------------------------R 49VU HYD/HYD/PRESS/XMTR 1841GN C11
R B. Aircraft Maintenance Configuration
R (1) Energize the aircraft electrical circuits
R (Ref. AMM TASK 24-41-00-861-002).
R (2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)

R (Ref. AMM TASK 31-60-00-860-001).
R (3) On the ECAM control panel on the center pedestal, push the HYD

R pushbutton switch. Make sure that the HYD page is shown on the system
R display of the ECAM.
R (4) Look for fault indications on the lower ECAM DU.
R (5) Monitor the condition of the circuit breaker 1841GN.
R 4. Fault Isolation

_______________

R A. If the Fault Confirmation gives:
R - The hydraulic system pressure indication of the Green, Blue and Yellow
R hydraulic system is replaced by amber XX on the lower ECAM DU.
R - The circuit breaker 1841GN is open:

R (1) Do a check for a defective hydraulic pressure transmitter as follows:

R (a) Remove the electrical connector from the HYDR. PRESSURE
R TRANSMITTER (1065GN).

R (b) Close the circuit breaker 1841GN:

R 1_ If the circuit breaker 1841GN stays closed:
R - Replace the HYDR. PRESSURE TRANSMITTER (1065GN) (Ref. AMM
R TASK 29-32-11-000-001) and (Ref. AMM TASK 29-32-11-400-001).

R 2_ If the circuit breaker 1841GN opens:

R a_ Connect the the electrical connector of the HYDR. PRESSURE
R TRANSMITTER (1065GN).

R (c) Do the worksteps (a) thru (b) again at the:
R - HYDR. PRESSURE TRANSMITTER (2065GN)
R - HYDR. PRESSURE TRANSMITTER (3065GN)

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-10-00∞∞∞∞∞∞∞∞∞∞Page 209
 May 01/05 CES

 

R  (d) Replace the applicable hydraulic pressure transmitter which 
R  causes the circuit breaker 1841GN to open: 
R  - for the HYDR. PRESSURE TRANSMITTER (2065GN) (Ref. AMM TASK 29-
R  32-11-000-002) and (Ref. AMM TASK 29-32-11-400-002) 
R  - for the HYDR. PRESSURE TRANSMITTER (3065GN)> (Ref. AMM TASK 29-
R  32-11-000-003) and (Ref. AMM TASK 29-32-11-400-003) 
R  (2) If the fault continues: 
R  (a) Do a check for continuity between: 
R  - the CB (1841GN) and the pin C of the terminal block (7502VT) 
R  (Ref. AWM 29-32-02). 
R  1_  If there is no continuity:
R  a_  Repair the wiring between the CB (1841GN) and the pin C of
R  the terminal block (7502VT) (Ref. AWM 29-32-02). 
R  b_  If the fault continues:
R  - Replace the C/B-HYDRAULIC/HYD/QTY/IND (1841GN). 
R  2_  If there is continuity:
R  - Do a check for continuity between the pin C of the terminal 
R  block (7502VT) and the pins D, E, H of the terminal block 
R  (7502VT) (Ref. AWM 29-32-02). 
R  a_  If there is no continuity:
R  - Replace the terminal block (7502VT). 
R  B. Do the applicable operational test of the hydraulic pressure transmitter, 
R  to make sure that the operation is correct (no fault indications shown): 
R  - For the HYDR. PRESSURE TRANSMITTER (1065GN) (Ref. AMM TASK 29-32-00-
R  710-001) 
R  - For the HYDR. PRESSURE TRANSMITTER (2065GN) (Ref. AMM TASK 29-32-00-
R  710-002) 
R  - For the HYDR. PRESSURE TRANSMITTER (3065GN) (Ref. AMM TASK 29-32-00-
R  710-003).

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-10-00∞∞∞∞∞∞∞∞∞∞Page 210
 May 01/05 CES

 

 GREEN MAIN HYDRAULIC POWER - FAULT ISOLATION PROCEDURES
_______________________________________________________
 TASK 29-11-00-810-801
 Loss of the Green Reservoir Pressurization
 1. Possible Causes
_______________

 - PRESS SW-G RSVR AIR (1384GH)

 - VALVE-MAN DEPRESS, G RSVR (1087GM)


 