• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:26来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (3) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).

 (4) Operate the sidestick for ailerons, spoilers and elevators at full travel for 5 min.

 (5) Operate the rudder pedals at full travel for 5 min.

 (6) Operate the flap and slat control lever at full travel for 5 min.


 4. Fault Isolation
_______________

 A. If the test gives:
 -the message HYD Y RSVR OVHT on the upper ECAM DU,
 -the PTU P/BSW FAULT light on panel 40VU,
 -the YELLOW ENG 1 PUMP P/BSW FAULT light on panel 40VU,
 -the OVHT flag on the HYD page of the lower ECAM DU:

 - measure the temperature with a temperature sensor adjacent to the XMTR-TEMP, Y RSVR (3381GR).
 (1) If the temperature is more than 95 +2.2 -2.2 deg.C (203.00 +3.96 -
3.96 deg.F):

 - do a check of the internal leakage of the Yellow hydraulic system (Ref. AMM TASK 29-00-00-280-003).
 NOTE : Make sure that the cargo door selector of the AFT cargo door
____ is not jammed in the OPEN or CLOSE position.
 (a) Do a check for local increase of the temperature and unusual noise specially at the subsequent components. Replace the components as necessary.
 1 CHECK VALVE- ELEC PUMP DELIVERY, Y (3083GM) (Ref. AMM TASK 29-
_
 24-21-000-001).

 a Do a visual inspection of the CHECK VALVE- ELEC PUMP
_ DELIVERY, Y (3083GM) for damage and missing parts.
 b If parts are missing, do the susequent before you install
_ the new check valve:
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-13-00∞∞∞∞∞∞∞∞∞∞Page 211
 Feb 01/01R CES

 

 - Examine the Yellow HP filter (3048GM) (Ref. AMM TASK 29-13-45-610-001) and the Yellow HP manifold (Ref. AMM TASK 29-13-14-000-001) and (Ref. AMM TASK 29-13-14-400-001) to find these parts.
 c Install the CHECK VALVE- ELEC PUMP DELIVERY, Y (3083GM)
_ (Ref. AMM TASK 29-24-21-400-001).
 2 RELIEF VALVE-HP, Y (3063GM) (Ref. AMM TASK 29-13-32-000-001)
_ and (Ref. AMM TASK 29-13-32-400-001).
 3 FILTER-RSVR RETURN, Y (3002GM) (Ref. AMM TASK 29-13-44-610-
_
 001).


 4 FILTER-HP, Y (3048GM) (Ref. AMM TASK 29-13-45-610-001).
_

 5 CHECK VALVE-HP FILTER, Y (3059GM) (Ref. AMM TASK 29-00-00-910-
_ 003). R
R 6_CHECK VALVE-HP MANIFOLD RETURN, Y (3022GM) (Ref. AMM TASK 29-00-00-910-003).
R 7_ RELIEF VALVE-BRK SYS, Y (3067GM) (Ref. AMM TASK 32-44-15-000-R 001) and (Ref. AMM TASK 32-44-15-400-001).
 (b) If the internal leakage is more than permitted:

 - examine the system to find the defective component,

 - replace or repair the defective component.

 

 (c) If the internal leakage is not more than permitted:

 - do a check of the filter elements of the FILTER-ENG 2 PUMP CASE DRAIN, Y (3084GM) , FILTER-HP, Y (3048GM) and FILTER- RSVR RETURN, Y (3002GM).

 (d) If the filter elements are dirty:


 - replace the filter element (Ref. AMM TASK 29-13-43-610-040) or (Ref. AMM TASK 29-13-44-610-001) or (Ref. AMM TASK 29-13-45-610-001)
 (2) If the temperature is less than 95 +2.2 -2.2 deg.C (203.00 +3.96 -
3.96 deg.F):

 - do a check for continuity between: XMTR-TEMP, Y RSVR (3381GR) connector A/A and connector A/B (Ref. ASM 29-33/01).
 (a) If there is continuity:
 - replace the XMTR-TEMP, Y RSVR (3381GR) (Ref. AMM TASK 29-33-11-000-003) (Ref. AMM TASK 29-33-11-400-003).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞29-13-00∞∞∞∞∞∞∞∞∞∞Page 212
 Feb 01/01 CES

 

 (b) If there is no continuity:
 - make sure that the wiring is not connected to GND between: XMTR-TEMP, Y RSVR (3381GR) connector A/B and the RELAY-Y RSVR OVHT FAULT (3705GD) connector Z (Ref. ASM 29-33/01) and (Ref. ASM 29-13/01).
 1 If the wiring is connected to GND:
_ - repair the wiring as necessary.

 (c) If the fault continues:
 - make sure that the wiring is not connected to GND between: XMTR-TEMP, Y RSVR (3381GR) connector A/B and the SDAC-1 (1WV1) connector 4G (Ref. ASM 29-33/01).
 1 If the wiring is connected to GND:
_ - repair the wiring as necessary.

 (d) If the fault continues:
 - make sure that the wiring is not connected to GND between: XMTR-TEMP, Y RSVR (3381GR) connector A/B and the SDAC-2 (1WV2) connector 4G (Ref. ASM 29-33/01).
 1 If the wiring is connected to GND:
 
中国航空网 www.aero.cn