 b Do a check of the aircraft log to see that the
_ microbiological contamination of the aircraft fuel tanks procedure has been complied with. If necessary, do (Ref. AMM TASK 28-11-00-600-004) (Ref. AMM TASK 28-11-00-600-007).
 c Refuel with fuel of the correct specification (Ref. AMM
_ TASK 12-11-28-650-003) (Ref. AMM TASK 12-11-28-650-004).
 d Do the test given in Para. 3.B.
_
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page D211
 May 01/05 CES


 (b) If a fuel probe capacitance value is not with-in range, replace the related LRU (Ref. TSM PB 101) for the related Task number(s).
 NOTE : The normal range of fuel probe capacitance values is given
____ in (Ref. TSM PB 301).
 NOTE : A fuel probe can fail and still stay within its range
____ and/or not be reported on the FQIS STATUS page.
 1 Do the test given in Para. 3.B.
_
 (c) If the capacitive values of related fuel probe LRUs attached to a FQIS fuel tank harness are shown blank, fluctuate or are outside the range of a similar group:
 1_ Do a check of the related aircraft wiring (including the
 common drive screen) between the FQIC rack-connector and the
 shorting plug as given in a procedure for a fuel probe in the
 given group.

 a Repair all the unserviceable wiring and connectors (Ref.
_ ESPM 20-00-00).
 2 Trouble shoot the related harness as given in a procedure for
_ a fuel probe in the applicable group.
 a If necessary, replace the applicable harness.
_ 3 Trouble shoot the fuel probes on the related harness.
_ Start with the multi-sensor (ULTRA COMP, DUAL COMP), if applicable, fuel probes first.
 4 Do the test given in Para. 3.B.
_
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page D212
 May 01/05R
 CES R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,


 TASK 28-42-00-810-875
 FQIs Degraded, Malfunction in a W/Tank when Fused Connector Plugs are Installed An Alternative Task for the Connector Plug Only and Caused by Moisture Ingress
 WARNING : OBEY THE FUEL SAFETY PROCEDURES.
_______
 1. Possible Causes
_______________
 - fused connector plug 4041VC-A

 - fused connector plug 4042VC-A

 - fused connector plug 4043VC-A

 - fused connector plug 4044VC-A


 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  multimeter
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
28-42-00-810-801  Fuel Quantity Indication Computer (FQIC) 3QT
 28-42-00-810-873  Fuel Quantity Probe - A Malfunction in the Wing Tank when Fused Connector Plugs are Installed - An Alternative Task (procedure) for the Connector Plug Only
 ESPM 20-52-22 AMM 05-25-70-200-004 Zonal Inspection of the False Spar Box AMM 28-42-00-740-003 Interrogation of the FQIS Input Parameters Pages ASM 28-42/05 ASM 28-42/06 ASM 28-42/07 ASM 28-42/08 TFU 28.42.00.039
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page D213
 201-299, 401-499, Aug 01/05 CES 3. Fault Confirmation


__________________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 Post SB 28-1087 For A/C 001-049,051-061,101-105,201-203,
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/FQI/CHAN/1 1QT A13 121VU FUEL/FQI/CHAN/2 2QT M27
 B. Test
 NOTE : This task gives an alternative procedure for trouble shooting a
____ degraded FQI display with a reported FQIC (3QT) malfunction. It is related to the wing-tank fused connector plugs only (fault caused by water/moisture ingress).
 