- between the C/B-FUEL/HI/LVL/SPLY (1QJ) and the refuel panel connector 4023VC pin <C
- between the DC1 ground point and the refuel panel connector 4024VC pin <J.
(6) Repair all the unserviceable wiring and connectors.
(7) Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞28-46-00∞∞∞∞∞∞∞∞∞∞Page A255
May 01/05 CES
(8) Panel Assy-Refuel (800VU) Internal Trouble-shooting, (Ref. AWM 28-46-02), and (Ref. AWM 28-46-03):
(a) Check/replace the SWITCH-TEST/HIGH/LTS (2QJ) (part of 800VU).
(b) Check/replace the diode between terminals 1 and 2 of diode module (4002VD) (part of 800VU).
(c) Check/replace the INDICATOR-HI LVL/RIGHT (4QJ) (part of 800VU).
(d) Check/repair the Panel Assy-Refuel (800VU) internal wiring as follows:
- connector 4023VC, pin <C to terminal block 4001VT, terminal 5C
- terminal block 4001VT, terminal 5E to IND-HI LVL/RIGHT (4QJ), terminal 4
- IND-HI LVL/RIGHT (4QJ), terminal 5 loop connection to terminals III, II, and I
- IND-HI LVL/RIGHT (4QJ), terminal II to terminal block 4001VT, terminal 2F
- terminal block 4001VT, terminal 2G to diode module 4002VD, terminal 1
- diode module 4002VD, terminal 2 to terminal block 4001VT, terminal 4H
- terminal block 4001VT, terminal 4B to SW-TEST/HI/LIGHTS (2QJ), terminal 3A
- SW-TEST/HI/LIGHTS (2QJ), terminal 1A to connector 4024VC, pin
<J.
(e) Install the Panel Assy-Refuel (800VU), (Ref. AMM TASK 28-25-55-400-001).
(f) Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞28-46-00∞∞∞∞∞∞∞∞∞∞Page A256
May 01/05 CES
TASK 28-46-00-810-822
CTR HI LVL Indicator Lamp Does Not Come On When TEST Switch Set To LTS
WARNING : OBEY THE FUEL SAFETY PROCEDURES.
_______
1. Possible Causes
_______________
- lamp
- Panel Assy-Refuel (800VU)
- C/B-FUEL/HI/LVL/SPLY (1QJ)
- aircraft wiring
- SWITCH-TEST/HIGH/LTS (2QJ) (part of 800VU)
- diode module (4002VD) (part of 800VU)
- INDICATOR-HI LVL/CTR (5QJ) (part of 800VU)
- Panel Assy-Refuel (800VU) internal wiring
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific multimeter
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 28-25-55-000-001 Removal of the Refuel Panel 800VU
AMM 28-25-55-400-001 Installation of the Refuel Panel 800VU
AMM 28-46-00-710-001 Test of the Tank High Level Sensing System
AWM 28-46-01
AWM 28-46-02
AWM 28-46-03
3. Fault Confirmation
__________________
A. Do up to and including Para. 3.A. of the Operational Test of the HI LVL Lights (Ref. AMM TASK 28-46-00-710-001).
NOTE : The OPEN DEFUEL/XFR lamp (21QU) should also come on during the
____
time the TEST switch is held at LTS.
The OPEN DEFUEL/XFR indicator lamp (21QU):
- 28VDC supply is from a different C/B
- switched ground/earth uses the same contacts of SWITCH-TEST/HIGH/LTS (2QJ).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞28-46-00∞∞∞∞∞∞∞∞∞∞Page A257
May 01/05 CES 4. Fault Isolation
_______________
A. If the CTR HI LVL indicator lamp only does not come on and the others do:
- replace the CTR HI LVL indicator lamp bulb. OR If at least one HI LVL indicator lamp comes on but others do not:
- replace the related lamps.
(1) If the fault continues or if none of the Panel Assy-Refuel (800VU) HI LVL indicator lamps come on:
(a) Remove the Panel Assy-Refuel (800VU) (Ref. AMM TASK 28-25-55-000-001).
(b) Do a check (Ref. AWM 28-46-01), and (Ref. AWM 28-46-02) with a multimeter to see if: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 FUEL 燃油4(101)