「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 352
201-299, 401-499, Aug 01/05 CES
-------------------------------------------------------------------------| | | MEAN | TOLERANCE | FULL TANK | | FIN | PROBE | THEORETICAL | AT DRY pF | pF | | | FUNCTIONAL DESIGNATION | pF DRY | + OR -| | |----------|------------------------|-------------|-----------|-----------|
R | | TANK No. 2 | | | | R | | | | | | R | 37QT * | PROBE-FUEL QTY, CTR | 81.86 | 0.82 | 170.98 | R | | TANK No. 3 | | | | R | | | | | | R | 38QT * | PROBE-FUEL QTY, CTR | 81.86 | 0.82 | 170.98 | R | | TANK No. 4 | | | | R | | | | | | R | 39QT * | PROBE-FUEL QTY, and | 59.49 | 0.60 | 124.28 | R | | PROBE-COMPENSATOR, CTR | 13.68 | 0.15 | 28.33 | R | | TANK No. 5 | | | | R -------------------------------------------------------------------------
R
R ----------------------------------------------------------------------------R | | | MEAN | | | R | | | THEORETICAL | | | R | FIN | PROBE | pF | TOLERANCE | FULL TANK | R | | FUNCTIONAL DESIGNATION |--------------| AT DRY pF | pF | R | | | DRY | EMPTY | + OR -| | R | | | | WET | | | R |----------|------------------------|------|-------|-----------|-------------| R | 19QT1(2) | SENSOR-CADENSICON L/R | 94.9 | 95.5 | 1.0 | 188.5-214.0 | R | | INNER CELL | | | | | R | | | | | | | R | 20QT * | SENSOR-CADENSICON CTR | 94.9 | 95.5 | 1.0 | 188.5-214.0 | R | | TANK | | | | | R ----------------------------------------------------------------------------
R For the additional values referred to in NOTE 1 above see R (Ref. Fig. 309) R The value on the vertical scale is the additional value of capacitance in pF R to be added to the MEAN THEORETICAL (MTV) when the fuel tanks are wet. R R EXAMPLE (Smiths FQIS) R R The MTV for Probe 21QT1 is 70.29pF. R R Immediately after draining an additional 0.25pF is to be added to this R value, (from slope 1). R 70.29 + 0.25 = 70.54pF R R After one hour this additional value will have reduced to 0.105pF, (from R slope 2). R 70.29 + 0.105 = 70.395pF R
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 353
201-299, 401-499, Aug 01/05 CES
Additional DC Capacitance Values When Empty Tank Probes are Wet R Figure 309
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 354
Aug 01/05 CES
R This later value will remain constant for sixty hours in a sealed tank.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 355
201-299, 401-499, Aug 01/05 CES
R 4. Optional Ground Support Equipment for the Fuel Quantity Indicating System_________________________________________________________________________
R and Fuel Level Sensing System.
R
R GENERAL
R The PSDA320-2 and PSDA320-3 Test Sets, PSDA320-4 and PSDA320-5 Interface
R Units are used to support the Fuel Quantity Indicating System (FQIS) and the
R Fuel Level Sensing System (FLSS) installed on the aircraft. When used
R together with the PSD30-2A Universal DC Fuel Quantity Test Set, they allow
R complete testing of all tank mounted components and aircraft wiring
R associated with the FQIS and FLSS.
R
R PSDA320-2 FLSS TEST SET - AT WING
R The PSDA320-2 Test Set allows access at the tank wall and provides test