PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C ALL
121VU EIS/HORN/SPLY 2WC P09 121VU HYDRAULIC/LGCIU/SYS2 2GA Q35 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
121VU ADIRS/ADIRU/2PWR/SHED 10FP N10 121VU ADIRS/ADIRU/3PWR/SWTG 9FP N09 121VU ADIRS/ADIRU/2/26VAC AND AOA 5FP2 N08 121VU ADIRS/ADIRU/3/26VAC AND AOA 5FP3 N07 121VU ADIRS/ADIRU/2/115VAC 4FP2 N06 121VU ADIRS/ADIRU/3/115VAC 4FP3 N05 121VU ADIRS/ADIRU/2/28VDC 6FP2 N04 121VU ADIRS/ADIRU/3/28VDC 6FP3 N03
1EFF : ALL 1 34-11-00Page 514 1 1 Aug 01/05 1 1 1CES 1
**ON A/C ALL
4. Procedure
_________
R **ON A/C 001-049, 101-105, 151-199, 201-203,
Subtask 34-11-00-710-051-A
A. Test of the Monitoring of the ADIRS Power Supply (115VAC-28VDC) NOTE : Ignore all warnings / indications which are not related to this
____
test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
On the panel 49VU (121VU):
- open the circuit breaker 4FP1 (4FP2).
2.
On the ADIRS CDU:
-
set the OFF/NAV/ATT selector switch related to the IR 1 (IR 2) to NAV.
-
set the SYS DISPLAY selector switch to 1 (2).
3.
On the panel 49VU (121VU):
-close the circuit breaker 4FP1 (4FP2).
- on the ADIRS CDU:
*
the ON BAT light is on,
*
the related ALIGN legend is on,
*
the related FAULT legend flashes.
- on the upper ECAM display unit, the IR 1 FAULT (IR 2 FAULT) warning comes into view.
- on the GLARESHIELD panels 130VU and 131VU, the MASTER CAUT lights are on.
-you can hear the single chime.
-after a time delay of 15 s, you can hear the horn.
- on the ADIRS CDU:
*
the related FAULT legend goes off,
*
the ON BAT light goes off,
*
the related ALIGN legend stays on.
1EFF : ALL 1 34-11-00Page 515 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- on the upper ECAM display unit, the
IR1 FAULT (IR2 FAULT) warning goes
out of view.
- the horn stops.
4. On the ADIRS CDU:
- set the OFF/NAV/ATT selector - on the ADIRS CDU, the related ALIGN
switch related to the IR 1 (IR legend goes off.
2) to OFF.
5. On the GLARESHIELD panels 130VU
and 131VU:
- push and release the MASTER - on the GLARESHIELD panels 130VU and
CAUT lights. 131VU, the MASTER CAUT lights go off.
6. Do the IR 2 test as specified in You must get the same results on the
para. 1 to 5. F/O side.
7. On the ADIRS CDU:
- set the OFF/NAV/ATT selector - on the ADIRS CDU:
switch related to the IR 1 (IR * the related ALIGN legend comes on,
2) to NAV. * then, the ON BAT light comes on
during 5 s.
8. On the panel 49VU (121VU):
- open the circuit breaker 4FP1 - on the ADIRS CDU, the ON BAT light
(4FP2). comes on.
- in the nose gear well:
* after a time delay of 15 s approx
you can hear the horn,
* on the door 121AL, on the EXT PWR
panel 108VU, the ADIRU & AVNCS VENT
light comes on.
- on the CAPT (F/O) PFD, the attitude
indications are shown.
9. On the panel 49VU (121VU):
- close the circuit breaker 4FP1 - on the ADIRS CDU, the ON BAT light
(4FP2). goes off.
R 1EFF : 001-049, 101-105, 151-199, 201-203, 1 34-11-00Page 516 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
10. On the ADIRS CDU:
-set the OFF/NAV/ATT selector switch related to the IR 1 (IR 2) to OFF.
11.
Do the IR 2 test as specified in para. 7 to 10.
12.
On the panel 121VU: - open the circuit breaker 4FP3.