• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 00:09来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the access door 824 (Ref. TASK 52-41-00-410-002).

 (3)
 Remove the access platform(s).


 1EFF : ALL 1 34-10-00Page 309 1 1 Aug 01/05R 1 1 1CES 1


 TASK 34-10-00-170-003
 Draining and Flushing of Standby Pneumatic Circuits
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 342100-02
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking cap
 No specific dry nitrogen source - 2 bars (29 psi)
 No specific access platform 1.6 m (5 ft. 3 in.)
 98D34003500000 2 ADAPTER COVER-STATIC PORT
 98D34103002000 1 ADAPTERS - AIR DATA SYSTEM FLUSHING
 98D34103003000 1 ADAPTER, PITOT - PNEUMATIC CLEANER
 98D34103004000 1 CLEANER - PITOT PROBE

 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
12-24-34-600-001 Bleeding of the Standby Air Data System 34-21-00-790-001 Low range leak test of standby pneumatic circuits 34-21-22-000-001 Removal of the Standby Altimeter (3FN) 34-21-22-400-001 Installation of the Standby Altimeter (3FN) 34-21-25-000-001 Removal of the Metric Altimeter (15FN) 34-21-25-400-001 Installation of the Metric Altimeter (15FN) 34-21-26-000-001 Removal of the Standby Airspeed Indicator (9FN) 34-21-26-400-001 Installation of the Standby Airspeed Indicator (9FN)
R **ON A/C 001-049, 051-099, 101-105,
 34-10-00-991-002 Fig. 302
 1EFF : ALL 1 34-10-00Page 310 1 1 May 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------

 

R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
 34-10-00-991-002-A Fig. 302A
 **ON A/C ALL

 3. Job Set-up
__________
 **ON A/C 001-049, 051-099, 101-105,

 (Ref. Fig. 302/TASK 34-10-00-991-002) R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 302A/TASK 34-10-00-991-002-A)
 **ON A/C ALL

 NOTE : The hose couplings are self-sealing.
____
 Subtask 34-10-00-010-061

 A. Get Access
 (1)
 Put the access platform in position in the zone 110 at the access door 811.

 (2)
 Open the access door 811.


 1EFF : ALL 1 34-10-00Page 311 1 1 Aug 01/05 1 1 1CES 1


 Location of Components Related to the Standby Pressure Lines-Schematic
 Figure 302/TASK 34-10-00-991-002

R 1EFF : 001-049, 051-099, 101-105, 1 34-10-00Page 312 1 1 May 01/05 1 1 1CES 1


 Location of Components Related to the Standby Pressure Lines-Schematic
 Figure 302A/TASK 34-10-00-991-002-A

R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 34-10-00Page 313 1401-499, 1Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-105,

 

 Subtask 34-10-00-860-053
 B. Aircraft Maintenance Configuration
 (1)
 Drain the standby air data system (Ref. TASK 12-24-34-600-001).

 (2)
 Disconnect the quick-disconnect coupling (4) from the ADM 19FP8 and the quick-disconnect coupling (8) from the ADM 19FP3.

 (3)
 Disconnect the cabin-pressure detection pressure-switch 14WN (3) from the static pipe. Put a blanking cap on the pressure switch.

 (4)
 Remove the water drain plug (2) from the water drain (1).

 (5)
 In the cockpit, on the center instrument panel:

 -
remove the standby altimeter 3FN (Ref. TASK 34-21-22-000-001)

 -
remove the standby airspeed indicator (6) 9FN (Ref. TASK 34-21-26-000-001)

 -
remove the metric altimeter (15FN) (Ref. TASK 34-21-25-000-001).

 

 (6)
 Disconnect the quick-disconnect coupling (7) from the red 2-pin coupling of the standby airspeed indicator (6) and disconnect the quick-disconnect couplings (5) from the yellow 3-pin couplings of the standby instruments 3FN, 9FN and 15FN.

 (7)
 Connect a ADAPTERS - AIR DATA SYSTEM FLUSHING 3-pin adapter (98D34103002100) to the hose of the standby altimeter and a ADAPTERS-AIR DATA SYSTEM FLUSHING 2-pin adapter (98D34103002102) to the hose (7). Then connect them to the dry nitrogen source - 2 bars (29 psi).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM NAVIGATION 导航1(44)