• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-11 13:04来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (2)  
Put the R HYD PUMPS ELEC switch, on the hydraulic control panel, in the ON position.

 S 215-301

 (3)  
Make sure the ACMP in the right hydraulic system, in the right wheel well, starts after 5 seconds.

 S 865-302

 (4)  
Put the R HYD PUMPS ELEC switch, on the hydraulic control panel, in the OFF position.

 S 215-303

 (5)  
Make sure the ACMP in the right hydraulic system, in the right wheel well, stops in less than 1 second.


 L.  Do a Test of the Alternating Current Motor Pumps (ACMPs) in the Center Hydraulic System With the Engines in Operation
 S 865-304
 (1)  Put these switches on the hydraulic control panel in the ON
 position:

 (a)  
C HYD PUMPS ELEC 1

 (b)  
C HYD PUMPS ELEC 2.


 S 865-305
 (2)  
Put the left and right BUS TIE switches, on the P5 panel, in the AUTO position.

 (3)
Put the R GEN CONT switch, on the P5 panel, in the ON position.

 S 865-307

 (4)  
Put these switches on the P5 panel in the OFF position:

 (a)  
L GEN CONT

 (b)  
APU GEN

 (c)  
EXT PWR.

 


 S 865-306
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-00
 ALL  ú ú 10 Page 533 ú Sep 28/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 S 215-308
 (5)  
Make sure the ACMP C2 in the center hydraulic system, in the aft left wing-to-body fairing, is not in operation.

 S 865-309

 (6)  
Put the right BUS TIE switch, on the P5 panel, in the ISLN position.

 S 215-310

 (7)  
Make sure the ACMP C2 in the center hydraulic system, in the aft left wing-to-body fairing, starts after 3 seconds.

 S 865-311

 (8)  
Put the right BUS TIE switch, on the P5 panel, in the AUTO position.

 S 865-312

 (9)  
Put these switches on the hydraulic control panel in the OFF position:

 (a)  
C HYD PUMPS ELEC 1

 (b)  
C HYD PUMPS ELEC 2.

 

 M.
Put the Airplane Back to Its Usual Condition


 S 865-313
 (1)  
Stop the left and right engines (AMM 71-00-00/201).

 S 865-314

 (2)  
Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 液压 CHAPTER 29 - HYDRAULIC POWER 1(87)