____ You can identify the plug with vents by the two holes in the flat surfaces of the hex.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-02
 ALL  ú ú 03 Page 406 ú Sep 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 CAUTION: YOU MUST REMOVE THE SOLID PLUG, P/N 73866, FROM THE SEEP
_______ PORT OF THE PUMP. IF YOU DO NOT REMOVE THIS PLUG, THE PUMP CAN BECOME TOO HOT.
 (b)  If a solid plug, P/N 73866, is in the seep port of the pump, remove the plug and the O-ring from the pump.
 NOTE: If the plug has vent holes, you must not remove it
____
 from the pump.

 S 434-023
 (6)  If necessary, install the vibration isolators (18) on the mounting plate (21).
 NOTE: All four vibration isolators must be the same part number.
____
 S 434-051
 (7)  
Install hydraulic pump (28) on the vibration isolators (18).

 S 434-024

 (8)  
Install the washers (23) and the bolts (22) to attach the vibration isolators (18) to the mounting plate (21).

 S 614-025

 (9)  
Fill the pump (28) with hydraulic fluid.

 S 434-026

 (10)
 Install the supply hose (6) on the pump (28).

 S 424-027

 (11)
 Put the pump (28) in position.


 NOTE:____The weight of the pump is 45 pounds. You must hold the pump until you install the bolts (24).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-02
 ALL  ú ú 03 Page 407 ú Sep 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 S 434-028
 (12)
 Connect the bonding jumper (16) to the pump (28) with the bolt (14), and the washers (15), if installed.

 S 034-029

 (13)
 Remove the nut (19) at the location of each bonding jumper (17).

 S 434-030

 (14)
 Install the bonding jumper (17) on the vibration isolator (18) with one washer (20) on each side of the jumper (17) and install the nut (19) (SWPM 20-20-00, of the Standard Wiring Practices Manual D6-54446 ).

 S 764-031

 (15)
 Do a check of the electrical resistance for the bonding jumper (SWPM 20-20-00, of the Standard Wiring Practices Manual D6-54446). The maximum resistance is 0.0001 ohm.
 