ELECTRICAL CONNECTOR
SUPPLY PORT
CASE DRAIN PORT RIPPLE DAMPER
MOTOR
PRESSURE PORT
VIBRATION ISOLATION BONDING STRAP
MOUNTS (4 PLACES) 29-11-0002
Alternating Current Motor Pump (ACMP) Figure 4
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 03 Page 6 ú Sep 20/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
BRACKET
C System Hydraulic Reservoir
Figure 5
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-00
ALL ú ú 01 Page 7 ú Dec 20/87
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
E. The depressurization valve is a manual valve located near the top of the reservoir. When a slider on the valve is held in the vented position the pneumatic line is shutoff and reservoir air pressure is vented. A valve lock can be installed to hold the valve slider in the vented position during maintenance. This valve lock must be removed before flight to allow the reservoir to be pressurized by the pneumatic system.
F. Each reservoir has two supply outlets. One outlet is connected to a standpipe inside the reservoir to retain a reserve fluid supply at the bottom of the reservoir. The second, or reserve, outlet is not connected to a standpipe and draws fluid from the bottom of the reservoir. In the left and right systems, the reservoir standpipe outlet supplies fluid to the EDP and ACMP. In the center system, the standpipe outlet supplies fluid to the two ACMP's. In the right system, the reserve outlet supplies fluid to the isolated ACMP supply shutoff valve for use in the reserve brakes system. In the left system, the reserve outlet supplies fluid to the power transfer unit (PTU) pump. In the center system, the reserve outlet supplies fluid to the ram air turbine (RAT) pump.